Installation fixture of indoor unit

*

INSTALLATION & REPAIR GUIDE

Split Wall-Mounted air conditioner

1.Installation of wall-mounting plate

Fix the wall-mounting plate firmly on the wall with screws.

Make sure of the leveling of the plate. Slanted wall-mounting

plate might jeopardize the smooth discharge of the condensed

water.

2.Drill holes on the wall

3.Installation of drain pipe

Install the pipelines of the indoor unit in accordance with

the direction of the wall holes. Wrap tightly the drain pipe

and the pipelines with tape. Make sure that the drain pipe

is underneath the pipelines. (Fig.3) (When the drain pipe

passes the room interior, some condensed water might

occur to its surfaces if the humidity is very high).

4.Installation of indoor unit

Pass the connection wires, connecting pipelines and drain

pipe through the wall hole. Hang the indoor unit on the

hooks at the top of the wall-mounting plate so that the

hooks at the bottom of the indoor unit match the hooks of

the wall-mounting plate. (Fig.4)

Fig.2

Fix with a tape

Wall cap

Wall pipe

Interior

Exterior

5-10mm lower

(1/5-2/5")

Wall

Fig.3

Pipelines of indoor unit

Drain pipe

Rear pipe

Bottom hooks

Hook supports

Top hooks

Fig.4

Drill holes at places slightly below the wall-mounting plate,

with hole diameter of 65mm(2-3/5") and the outer edge of

the hole 5-10mm(1/5-2/5") lower (Fig.2) so that the condensed

water can smoothly flow out. Cut the wall penetrating pipe

to proper length according to the thickness of the wall (3-

5mm(1/10-1/5") longer than the wall thickness) and insert

the pipe as indicated in Fig.2.