Т³гж 20, 19 installation instructions, Floor and standing type (console) – Pridiom Condenser Installation Manual User Manual

Page 20: 5 the dimension of the unit, 1 accessories(console), Unit:mm, Fig.43-1

Advertising
background image

19

INSTALLATION INSTRUCTIONS

4.5 The Dimension of the Unit

Unit:mm

Capacity

12-18

A

B

D

E

F

G

H

C

990 660

206

505

506

907

200

203

Note:The dimension of 12000Btu/h and
18000Btu/h are the same.

5. Floor and Standing Type

(Console)

5.1 Accessories(Console)

Please check whether the following fittings
are of full scope. If there are some spare
fittings, please restore them carefully.

SHAPE

QUANTITY

NAME

1.Hook

6. Owner's manual

7. Installation manual

2. Remote controller

3. Frame

5. Alkaline dry batteries

(AM4)

2

1

1

2

2

1

1

4. Mounting screw

(ST2.9 10-C-H)

Installation
fittings

Remote
controller
& Its Frame

Others

Cautions on remote controller installation:

Never throw or beat the controller.
Before installation, operate the remote
controller to determine its location in a
reception range.
Keep the remote controller at least 1m apart
from the nearest TV set or stereo equipment.
(it is necessary to prevent image
disturbances or noise interferences.)
Do not install the remote controller in a place
exposed to direct sunlight or close to a
heating source, such as a stove.
Note that the positive and negative poles
are right positions when loading batteries.
This manual is subject to changes due to
technological improvement without
further notices.

Remote

controller

Remote controller

holder

Mounting screw B
ST2.9x10-C-H

SET TEMPERATURE£¨

O

C)

AUTO
COOL

DRY

HEAT

FAN
HIGH
MED
LOW

TEMP.

MODE

ON/OFF FAN SPEED

SWING ECONOMIC TIMER ON

RESET LOCKTIMER OFF

AIR DIRECTION

POWERFUL

Fig.43-1

5.2 Inspecting and Handling the
unit(Console)

5.3 Indoor Unit Installation(Console)

At delivery, the package should be
checked and any damage should be
reported immediately to the service agent.
When handling the unit, take into account
the following:
1. Fragile, handle the unit with care.
2. Keep the unit upright in order to
avoid compressor damage.
3. Choose on before hand the path along
which the unit is to be brought in.
4. Move this unit as originally package as
possible.
5. When lifting the unit , always use
protectors to prevent belt damage and
pay attention to the position of the
unit s centre of gravity.

,

5.3.1 Installation place

The indoor unit should be installed in a
location that meets the following
requirements:
There is enough room for installation and
maintenance.

(Refer to Fig.43-2 & Fig.43-3)

The outlet and the inlet are not impeded,
and the influence of external air is the
least.
The air flow can reach throughout the
room.
The connecting pipe and drainpipe could
be extracted out easily.
There is no direct radiation from heaters.

Advertising