Т³гж 28, Mono models multi models, Electrical work 27 – Pridiom Condenser Installation Manual User Manual

Page 28: Fig.58 fig.59, Mono, Mono multi

Advertising
background image

NOTE:

For some models, the indoor unit is especially designed to used as either MULTI models
or MONO models. If your air conditioner is not set to the MULTI position, see the following
INDOOR WIRING DIAGRAM to modify the indoor unit from MONO model to MULTI model.
(Fig.56 & 57)
1. Carefully remove the front panel and frame, then remove the Electricall control cover
by loosen the screw.
2. Remove the POWER SUPPLY cord of MONO model(Fig.56).
3. Unplug the “L” RED wire connected with “4” on pinboard of RY1, then connect it
with “3” on pinboard of Ry1.
4. Reinstall the Electrical Control cover and screw, rip off the white paper above the
Slide Switch and move it to the MULTI position(see Fig. 56).
5. Reinstall the front panel and frame.
6. Now the indoor unit can be used as MULTI models(Fig.57). Because the control
system is changed, the AUTO CLEAN function is unavailable for MULTI models.

MONO MODELS

MULTI MODELS

MONO

MONO

MULTI

Rip off the
white paper

MONO

MONO

MULTI

Fig.58

Fig.59

ELECTRICAL WORK

27

RED

RED

4

4

3

3

3

3

3

3

2

2

PLUMB STEP MOTOR

DOOR STEP MOTOR

This symbol indicates the element
is optional,the actual shape shall
be prevail.

Notes:

RED

RED

4

4

3

3

3

3

3

3

2

2

PLUMB STEP MOTOR

DOOR STEP MOTOR

This symbol indicates the element
is optional,the actual shape shall
be prevail.

Notes:

202032590637