Tjernlund DCOP1 Constant Operating Pressure Draft Control 8504174 (Discontinued) User Manual

Page 12

Advertising
background image

11

UC1 UNIVERSAL CONTROL CONNECTED TO A HONEYWELL R7184 SERIES OR EQUIVALENT

PRIMARY CONTROL WITH A LINE VOLTAGE THERMOSTAT OR AQUASTAT

Jumper

Low Voltage

or Aquastat Control

Line Voltage Thermostat

Ignitor

JUMPER

CALL

LEGEND:

115 VAC

IMPORTANT:

AS APPLIANCE INTERLOCK VOLTAGE.

RED JUMPER POSITION MUST BE THE SAME

J2

J1

XN

UNI

V

E

R

S

A

L

CO

NT
RO

LLE

R

XL

115V

DR

Y

24V

Limit

SUPPLY

60 Hz

115 VAC

OIL VALVE

L2

T

T

L1

R7184

Limit

Oil Valve

R

BURNER MOTOR

IGNITION TRANS

A

Motor

Intermittant

Interrupted

A

Cad Cell

Alarm

Burner

FIGURE 8050035 3-29-11

FACTORY WIRED TO

L AND N ON DCOP1

1. Disconnect burner motor wire off the R7184.
2. Connect burner motor terminal of R7184 to #1 on UC1 terminal block.
3. Connect #2 on UC1 terminal block to L2 or N.
4. Connect #4 on UC1 terminal block to burner motor wire removed from R7184.
5. Make sure RED voltage jumper on UC1 is on 115V.

UC1 UNIVERSAL CONTROL CONNECTED TO A GAS OR OIL BURNER WITH AN AQUASTAT

FROM PRIMARY CONTROL / CAD CELL RELAY.

WHEN INTERLOCKING WITH AQUASTAT DO NOT DISCONNECT BURNER MOTOR

CAUTION:

AS APPLIANCE INTERLOCK VOLTAGE.

IMPORTANT:

RED JUMPER POSITION MUST BE THE SAME

RELAY OR GAS VALVE

JUMPER

CALL

LEGEND:

115 VAC

L2

L1

C2

C1

B1

B2

AQUASTAT

24V

DRY

115V

J2

J1

XL

N

L1

PRIMARY CONTROL, BURNER

LINE VOLTAGE OIL BURNER

UN

IVER

SAL CONT

ROL

L

E

R

R

XN

FIGURE 8050034 3-29-11

FACTORY WIRED TO

L AND N ON DCOP1

1. Disconnect B1 from L1 of oil burner primary control, burner relay or hot of gas valve and reconnect to #1 on UC1 terminal block.
2. Connect #2 on UC1 terminal block to B2 or N.
3. Connect #4 on UC1 terminal block to the L1 on line voltage oil burner primary control, burner relay or gas valve.
4. Make sure RED voltage jumper on UC1 is on 115V.

NOTE: If burner safety control goes out on lockout, the Inducer will continue to run as long as a call for heat is present.