UC1 UNIVERSAL CONTROL CONNECTED TO AN OIL-FIRED FURNACE WITH A

HONEYWELL T87 OR EQUIVALENT NON-POWERED THERMOSTAT

R

XL

XN

J1

HONEYWELL T87 OR EQUIVALENT

NON-POWERED THERMOSTAT

1

15V

J2

LOW VAC

POWER.

DO NOT SUPPLY POWER!

115 VAC

LEGEND:

5 VDC BOARD-GENERATED

IMPORTANT:

BACKFEEDS OR SHORT

REMOVE JUMPER TO AVOID

24
V

DRY

CIRCUITS.

FIGURE 8050037 3-29-11

FACTORY

WIRED TO

ON DCOP1

L AND N

IMPORTANT:

RED JUMPER POSITION MUST BE THE SAME

AS APPLIANCE INTERLOCK VOLTAGE.

PRIMARY CONTROL

UNIVERSAL CONT

ROLLER

OR EQUIVALENT

BLACK

ORANGE

WHITE

WIRED

FACTORY-

R8184 SERIES

O

HONEYWELL

W

F

F

B

T

T

1. IMPORTANT: Remove J1 & J2 Call Jumper on UC1 to avoid backfeeds or short circuits.
2. Connect T87 or Equivalent non-powered thermostat to A and B terminals on UC1.
3. Remove T T Jumper from R8184 or equivalent Primary Control.
4. Connect #3 on UC1 terminal block to T terminal of Primary Control.
5. Connect #4 on UC1 terminal block to remaining T terminal of Primary Control.
6. Make sure RED voltage jumper on UC1 is on DRY.

NOTE: If burner safety control goes out on lockout, the Inducer will continue to run as long as a call for heat is present.

Jumper

Low Voltage

or Aquastat Control

Limit

JUMPER

CALL

LEGEND:

115 VAC

24V

DR

Y

115V

IMPORTANT:

AS APPLIANCE INTERLOCK VOLTAGE.

RED JUMPER POSITION MUST BE THE SAME

J1

XL

XN

U

N

IVER

SAL C

O

N

T

R

O

LLER

J2

SUPPLY

60 Hz

Line Voltage Thermostat

10 FLA / 60 LRA

500 VA

IGNITION TRANS

BURNER MOTOR

115 VAC

T

Red/White

Black

T

White

F

F

Orange

Blue

A

R

OIL VALVE

0.3 A, AC

Violet

A

Alarm

FIGURE 8050036 3-29-11

FACTORY WIRED TO

L AND N ON DCOP1

1. Disconnect burner motor wire off the Orange on Carlin.
2. Connect burner motor terminal Orange of Carlin to #1 on UC1 terminal block.
3. Connect #2 on UC1 terminal block to L2 or N
4. Connect #4 on UC1 terminal block to burner motor wire removed from Orange of Carlin.
5. Make sure RED voltage jumper on UC1 is on 115V.

UC1 UNIVERSAL CONTROL CONNECTED WITH A CARLIN 40200, 42230, 48245, 50200, 60200

SERIES OR EQUIVALENT AND A LINE VOLTAGE THERMOSTAT OR AQUASTAT