Installation, Plumbing requirements – B&C Technologies DP-250 Industrial User Manual
Page 34
Installation
Plumbing Requirements
The DE series dryer can be equipped with an
optional fire suppression system to reduce the
risk of fire in your dryer. If so equipped,
connect the water supply to the 3/4” GHT
connection, located on the upper right rear of
the machine as labeled.
90C / 195F MAX
0.7-7.0 BAR / 10-100 PSI
If fire suppression activates, the blower will
stop, the cylinder will rotate in the forward
direction, and the emitters will lightly mist the
goods until the temperature drops to a safe
level.
To avoid fires, keep the equipment clean, as
detailed elsewhere in this manual, and always
program cool down time. No cool down time,
or stopping the machine before the cycle has
completed can cause fires, as spontaneous
combustion can occur in the drying cylinder.