Pilz PSEN op2H-s-30-180/1 User Manual

Page 11

Advertising
background image

Instruction Manual

PSEN op2H-s Series

7

NOTE: K value is:

2000 mm/s if the calculated value of S is ≤ 500 mm

1600 mm/s if the calculated value of S is > 500 mm


When devices with >40 mm resolution are used, the height of the top
beam has to be

≥ 900 mm (H2) from machine supporting base while

the height of the bottom beam has to be

≤ 300 mm (H1).

If the safety light curtain must be mounted in a horizontal position
(Fig.4), the distance between the dangerous area and the most
distant optical beam must be equal to the value calculated using the
following formula:

S = 1600 mm/s (t

1

+ t

2

) + 1200 – 0.4 H

where:

S = Minimum safety distance in mm.
t

1

=

Response time of the AOPD

in seconds

(

see section 9 “Technical data”)

t

2

=

Machine stopping time in seconds.

H = Beam height from ground; this height must always be less than
1,000 mm.

Fig. 4

Advertising