Pilz PSEN op2H-s-30-180/1 User Manual

Page 8

Advertising
background image

PSEN op2H-s Series

Instruction Manual

4

1.3. How to choose the device

There are at least three different main characteristics that should be
considered when choosing a safety light curtain, after having
evaluated the risk assessment:

1.3.1. Resolution

The resolution of the device is the minimum dimension that an
opaque object must have in order to obscure at least one of the
beams that constitute the sensitive area.
The resolution strictly depends on the part of the body to be
protected.

R = 30 mm

hand protection

Type 2

As shown in Fig.1, the resolution only depends on the geometrical
characteristics of the lenses, diameter and distance between centres,
and is independent from any environmental and operating conditions
of the safety light curtain.

Fig. 1


The resolution value is obtained applying the following formula:

R = I + d

where:

I = Distance between two adjacent optics
d = Lens

diameter

Advertising