7.2. Diagnostic messages

The operator is able to check the main causes of the system stop
and failure, using the same LEDs used for visualising the functions.

For Receiver:

Function

Status

Meaning

LED

Normal operation

TEST

(red ON)

Light curtain being tested, the
OSSD status shall be OFF

Emission

(OSSD ON)

(green ON)

Light curtain working and in
standard operating conditions

Interruption

(OSSD OFF)

(red ON)

Light curtain working and in
safety block conditions.

Function

Type

Check and repair

LED

Error status

OSSD error
(yellow and red
BLINKING)

Check OSSD connections;
make sure that they are not in
contact with one another or
with the supply cables, then
Reset. If the failure continues
contact Pilz

Internal error
(red ON, yellow
BLINKING)

Switch OFF and switch ON
the supply circuit; if the failure
continues contact Pilz

Optical error
(red ON, yellow
BLINKING)

Reset. If the failure continues
contact Pilz

No power
supply

(LEDs OFF)

Check connections and input
voltage correct value.

If the failure continues contact
Pilz