7-23

7.5

Setting the parameters for bending angle measurement

7

Commissioning

7.5

Setting the parameters for bending angle measurement

7500

Setting the parameters for bending angle measurement

7-

Inbetriebnahme_Biegewinkelmessung_parametrieren

Prerequisite: The PSENvip must be in NORMAL OPERATION status.

To set the parameters for bending angle measurement, follow the in-
structions below:

Press the <MODE> key.

Using the keys , select the MEASUREMENT option.

Press the <ENTER> key.

The menu for setting the parameters for bending angle measurement will
appear.

Fig. 7-20:

Setting the parameters for bending angle measurement

A maximum of 5 angles can be monitored to check that they stay within
a tolerance. The accuracy of the measurement can be set.

Select ANGLE 1 to ANGLE 5 or ACCURACY using the keys

Press the <ENTER> key.

Change the parameter

Select the parameter using the keys

Press the <ENTER> key.

The arrow will be shown in bold. The parameters can now be
changed.

Press the

keys to change the parameters.

Press the <ENTER> key to accept the values.

You can exit parameter setting at any time without confirming the en-
try by pressing <ESC>. In this case, the previous values will be re-
tained.