4.4.2

Transmitter

Transmitter

4-

Funktion_Geraete_Sender_Stecker

The top of the transmitter has a 4-pin M12 connector.

4.4.2.1

Inputs

Inputs

4-

Funktion_Geraete_Sender_Eingang_TRM_ON_TRM_SYNC

The receiver uses these standard inputs to control the transmitter's light
source. The user cannot influence these internal signals.

TRM_ON

The receiver uses this signal to switch the transmitter's light source
on and off.

TRM_SYNC

The receiver uses this signal to control the intensity of the transmit-
ter's light source.

4.4.3

Receiver

Receiver

4-

Funktion_Geraete_Empfaenger_Stecker

The top of the receiver has two 8-pin M12 connectors.

4.4.3.1

Inputs

Inputs

4-

Funktion_Geraete_Empfaenger_Eingaenge_1_Basis

System-Init

Input whose signal comes from the CNC controller.
System-Init = 1: Press at top dead centre or in an upward movement
System-Init = 0: Downward movement
The PSENvip can perform internal safety tests when System-Init = 1.
The OSSD is in the OFF state (OSSD = 0).

Funktion_Geraete_Empfaenger_Eingaenge_2

Funktion_Geraete_Empfaenger_Eingaenge_3

INFORMATION
Please note that the PSENvip independently carries out an inter-
nal safety test every 2 minutes, if such a test is not requested
within this time by an external control system through System-
Init = 1. The PSENvip switches the OSSDs off during the safety
tests. For this reason you should ensure that the safety tests are
requested by an external control system before these 2 minutes
have elapsed. The best time to do this is when the OSSDs are
already switched off due to the position within the press stroke,
e.g. at top dead centre.