8.2
Operating notes
8
Operation
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
8-4
Press the <ENTER> key to activate bending angle measurement.
The measured value is shown on the receiver's display.
Additional information is only available if the angles to be measured
are set to ACTIVE in the MEASUREMENT menu.
Press the <MODE> button to obtain additional information.
The display shows the following:
– Angle image
– ANGLE: Measured value
– MARGIN: Specified set value and tolerance
Measured value lies within one of the 5 possible set values:
– MARGIN: Set value and tolerance are displayed, e.g. 90.0/0.5
– LED : lights up blue
Measured value lies within none of the 5 possible set values:
– MARGIN: - / -
– LED : off
Fig. 8-2:
Measure bending angle
Press the <ENTER> or <ESC> keys to exit bending angle measure-
ment.
SYSTEM OK OSSD OFF
MEASUREMENT
ANGLE
90.4
MARGIN
90.0/0.5