Pilz PNOZ s30 24-240VACDC 2 n/o 2 n/c User Manual
Page 46
Advertising

Commissioning
Operating Manual PNOZ s30
1001715-EN-13
46
Other, pre-defined settings:
}
Switch functions
–
Direction (F3)
Direction left
Tolerance for wrong direction = 10 Imp
–
Direction (F4)
Direction right
Tolerance for wrong direction = 10 Imp
}
Parameter set/select input
P0, select inputs are ignored (Select inputs mode: "None")
}
Hysteresis
Standstill and speed, 2 % each
}
Output assignment
– Standstill: Relay output Rel. 1 and semiconductor output Out 1
– Speed: Relay output Rel. 2 and semiconductor output Out 2
– Direction left: External output Ext. 1 and semiconductor output Out 3
– Direction right: External output Ext. 2 and semiconductor output Out 4
}
Reset mode
– All outputs: Automatic reset
}
Switch delay
None
}
Max. encoder frequency
1 MHz