3-30

N525 Ethernet Termination Service Unit

4. At the prompt, select the Source, which is the inactive bank for the local module, then

select the Destination, which is the inactive bank for the remote module, and press
<Enter>; the upgrade runs automatically.

To run the new software, swap banks, and reset the module. Follow these steps:

1. From the Main Menu, type [

7

], "Software Upgrade," and press <Enter>.

2. At the Software Upgrade Menu, type [

2

], "Swap Bank & Reset," press <Tab> to highlight

the Remote column, and press <Enter>.

3. Type [

2

], "Swap Bank & Reset," check that the Local column is highlighted, and press

<Enter>. Both modules reset and start using the new firmware.


------------------------------------SOFTWARE UPGRADE----------------------------

Time Since Last Restart 2 days 13:53:23



Local Remote Offline

Last Data
Active Firmware 96.05
Inactive Firmware 12.15

Bootcode 06.30

1) Software Reset Reset Reset

2) Swap Bank & Reset Swap Swap

3) Get New File with TFTP



Select [1-3]:



------------------------------------Messages------------------------------------


Swap