CANOGA PERKINS N525 Ethernet Termination Service Unit User Manual

Page 64

Advertising
background image

3-46

N525 Ethernet Termination Service Unit

d. Link Loss Fwd

Enables or Disables Link Loss Forwarding (LLF). Pressing <Space> cycles through
the options. Options are Disabled, User – Ext, Ext – User, and Both Directions.

When Link Loss Forwarding (LLF) is enabled, a fault on one side of the N525
propagates to the other side to notify that device and stops signal transmission
(brings down the link). See Figure 19. Set the LLF propagation to User to Extension,
Extension to User, or both directions. Set this in the User Interface at the Functional
Configuration screen (see

Managing the Network Interface

).

Figure 23 - Link Loss Forwarding Propagation

e. Flow Control

Enables or Disables flow control on the Remote port. Pressing <Space> cycles
through the options. Options are Disabled, Ext Port Enabled.

f. Maximum Frame Size: Sets maximum allowable Ethernet Frame size the N525 will

forward. Size range is 1518-10000.

g. Sideband Management

Enables or disables SideBand Management Channel (SBMC) communications with
a remote N525, L351 or L357. When enabled, pressing <Ctrl-L> verifications SMBC
connectivity with the remote unit.

h. Remote Configuration

Displays Functional Configuration of SBMC connected remote N525, L351 or L357.

4. To return to the Main Menu, press <Esc>.

Advertising