Configuring cld – CANOGA PERKINS N525 Ethernet Termination Service Unit User Manual

Page 88

Advertising
background image

4-12

N525 Ethernet Termination Service Unit

Configuring CLD

To set up CLD, follow these steps:

1. On the Diagnostics screen, type the number for "Remote Connectivity Loss Detection"

and press <Enter>. The Connectivity Loss Detection screen appears. There are four
submenus.

2. Type 1 for "CLD Configuration" and press <Enter>. The CLD Configuration screen

appears.

Note: All event pairs are reported alternately. Event pair example: RTT Max Threshold/RTT
Restoration Threshold.

a. Enable CLD

Enable or disable CLD on this N525.


---------------------------CONNECTIVITY LOSS DETECTION--------------------------

1) CLD Configuration
2) CLD Profile
3) CLD Trap Configuration

4) CLD Statistics

Select [1-4]:









------------------------------------Messages------------------------------------



-------------------------------CLD CONFIGURATION-------------------------------

1) Enable CLD : Enabled

2) Local CLD IP Address : 10.10.140.160

Subnet Mask Size (Bits) : 16
3) Remote CLD IP Address : 10.10.140.8
Connectivity Events

4) Consecutive Pings for Connectivity Loss : 3
5) Consecutive Pings for Connection Restored : 150
Round Trip Time (RTT) Events

6) RTT Max Threshold (ms) : 150
7) RTT Restoration Threshold (ms) : 90
Connection Loss Forwarding (CLF) Events

8) Connection Loss Forwarding: : Enabled
Consecutive Lost Pings for CLF Shutdown : 3
9) CLF Restore User Port Mode: : Auto

Consecutive Pings for CLF Restored : 10

Select [1 9]:

-----------------------------------Messages------------------------------------