Operating Instructions and Assembly Instructions

Airless Paint Sprayers

ClEANUP FOr ChANGING PAINTS

Or TEmPOrAry STOrAGE FOr

mOrE ThAN ONE NIGhT

wEAr All NECESSAry

SAFETy GEAr

NECESSAry TOOlS / mATErIAlS:

• Rag
• Gloves
• Two (2) buckets
• At least one (1) gallon of clean-

ing fluid (water or mineral spirits

depending on coating type)

• cleaning brush

NOTE: Do NOT disconnect any hoses.

1. Turn prime/spray control to PRIME

position.

2. Turn power switch to ON.

High pressure

hose may still be

pressurized with prime/spray control

in the pRiME position. with the gun

pointed in a safe direction, pull the

gun trigger to relieve any pressure in

the hose.

3. Turn pressure to HIGH (completely

clockwise).

4. Lift suction assembly above fluid

level in bucket.

While holding suction assembly
above paint level, allow pump to
run until empty.

5. Immediately place both suction

assembly and bypass tube in a
bucket containing enough cleaning
fluid to cover suction filter by two
inches. Allow pump to prime and
begin circulating fluid.

6. While fluid is circulating, soak rag

in fluid and wipe exterior of suction
assembly and bypass tube. Remove
suction filter. Wipe suction filter
with rag removing excess paint
buildup. Reinsert filter into suction
tube.

Cleaning Pump

Turn Pressure to HIGH

(completely clockwise)

3

4

Lift Suction Assembly above

Paint Level in Bucket

www.chpower.com

Turn Prime/Spray

Control to PRIME

Position

1

6

Wipe Exterior of Suction

Assembly and Bypass Tube

Suction Assembly and

Bypass Tube in Bucket

of cleaning fluid

11

2

Turn power switch to ON

(shown in the OFF position)

5