background image

Airless Paint Sprayers

7

Operating Instructions and Assembly Instructions

www.chpower.com

Turn Pressure

to HIGH

(completely clockwise)

4

Starting Instructions

While Pulling Trigger,

Direct Fluid Stream Along

Inside of Bucket

7

Power Switch

Location

3

Tip in

CLEANING

Position

6

5

Turn Prime/ Spray

Control

to SPRAY

(knob is horizontal)

Preparation (Continued)

1. Place both suction and bypass tubes

in cleaning solvent.

2. Turn prime/spray control to the

PRIME position.

3. Turn power switch to the ON

position.

4. Turn pressure to HIGH (completely

clockwise). In a few seconds,
cleaning solvent will begin to move
up through the tube. Allow the fluid
to circulate for one minute to ensure
all air has been exhausted from the
pump.

5. Turn prime/spray control to SPRAY

position. Watch for any fluid leaks
(See Troubleshooting Chart if leaks
occur).

NOTE: If unit is building pressure
properly the pump should turn off,
which indicates it has reached its user
set pressure.
6. When flushing the system with

cleansing fluid (either prior to
use with paint or during cleaning
process) the spray tip can remain in
the CLEAN position.

7. Point spray gun into an empty waste

bucket and pull trigger. To reduce
splashing, direct the fluid stream
along the inside of the bucket wall
and well above the fluid level.

1

Place Suction Tube

and Bypass Tube in

Solvent

Turn Prime/ Spray

Control

to PRIME

(knob is vertical)

2

Advertising