Airless paint sprayers – Campbell Hausfeld PS120B User Manual

Page 4

Advertising
background image

4

Operating Instructions and Assembly Instructions

Airless Paint Sprayers

SkIN INjECTION hAzArD:

High pressure spray can inject toxins

into blood stream. If injection
occurs, seek emergency medical
treatment.

use a face mask/respirator
and protective clothing
when spraying. Always
spray in a well ventilated area to
prevent health and fire hazards. Refer
to Material Safety Data Sheets (MSDS)
of spray material for details.

Never try to stop leaks with any

part of your body.

This system is capable of producing

2800 psi (19 300 kPa). Use only
Campbell Hausfeld replacement
parts rated at 2800 psi (19 300 kPa)
or higher.

To reduce the risk of
skin injection:

Do not aim the

gun at, or spray,
any person or
animal.

Keep hands and other body parts

away from the discharge. For
example, do not try to stop leaks
with any part of the body.

Do not clean spray tip while it is

attached to the spray gun. Remove
spray tip from gun to clean tip
guard.

Always use the nozzle tip guard. Do

not spray without nozzle tip guard
in place.

Do not remove tip while cleaning

the pump.

Only use a nozzle tip specified by

the manufacturer.

Use caution when cleaning and

changing nozzle tips. Before

www.chpower.com

removing the nozzle tip, follow
the manufacturer’s instructions for
turning off the unit and relieving
the pressure.

Do not leave the unit energized or

under pressure while unattended.
When not in use turn off the
unit and relieve the pressure in
accordance with the manufacturer’s
instructions.

High pressure spray is able to inject

toxins into the body and cause
serious bodily injury. In the event
that injection occurs, seek medical
attention immediately.

Check parts for signs of damage.

Replace any damaged parts.

This spray gun is rated for 3000 psi

(20 500 kPa). Do not use on systems
designed to produce more than
3000 psi (20 500 kPa).

Always engage the trigger lock
when not spraying. Verify the
trigger lock is functioning properly.
• To lock (engage): rotate tabs on

lock to horizontal position.

• To unlock (disengage) to spray:

rotate tabs on lock to vertical
position.

NOTE: If gun sprays while in the locked
position follow instructions in Spray
Gun Maintenance section for trigger
lock.

Verify that all connections are

secure before operating. Do not
use pliers to tighten or loosen high
pressure connections.

Know how to stop your unit

and bleed pressure quickly. Be
thoroughly familiar with the
controls.

Motor is equipped with an

automatic thermal overload. Motor
will restart without warning, after
cooling.

Never aim or

spray at yourself

or anyone else or serious injury could
occur.

LOCKED

TO UNLOCK

UNLOCKED

TO LOCK

Advertising