3.1.1 Collector Temperature
Shows the current collector temperature.
• COL : collector temperature
COL:
Collector Temperature
display range: -40
→+482 °F
3.1.2 Lower Storage Tank Temperature
Shows the current store temperature.
• TST : store temperature
TST:
Store Temperature
Display range: -40
→+482 °F
3.1.3 Sensor 3 or 4
Shows the current temperature of the corresponding ad-
ditional sensor (without control function).
• S3
: sensor 3 temperature
• S4
: sensor 4 temperature
Please note:
S3 and S4 are only indicated if the temperature sensors
are connected (shown).
S3, S4:
Sensor Temperatures
Display range: -40
→+482 °F
3.1.4 Other Temperatures (if applicable)
Shows the current temperature of the sensor.
• TRF : return flow temperature
TRF:
Return Flow
Tempe rature
Display range: -40
→+482 °F
3.1.5 Operating Hours Counter
h P:
Number of hours which
relay 1 has been active
The operating hours counter adds up the solar operating
hours of the relay (h P). The total amount of hours which
the relay has been active is shown on the display.
The operating hours total can be reset. As soon as the oper-
ating hours channel is selected, the symbol
is displayed
solid. To reset the operating hours press and hold the middle
key (key 3) for approximately 5 seconds. The set symbol
blinks. Press key 3 again and the operating hours counter
is reset to 0.
In order to interrupt the RESET-procedure, don’t press any
button for about 5 seconds. The controller returns automa-
tically into the display mode.