Carrier 50RTG User Manual

Page 8

Advertising
background image

8

SEE NOTE 5

SEE NOTE 6

NOTE 4

SEE

Not Used

R

Status

RV

AL2

AL1

Relay

Alarm

A

C

JW1

LED

Control Logic

Microprocessor

C

G

DC

CO

EH2

EH1

CO

24V

P3

FP2

FP1

BRG

Test Pins

C

P1

R

O

G

W

Y

Y

BR

Not Used

Dip Switch

PM

Compressor

Off On

1
2

Relay

FP2

FP1

HP

LOC

P2

CC

CCG

1

2

4

3

6

5

8

7

10

9

12

VIO

VIO

FP2

BRN

ORG

RVS

TR1

TR

S

+

S

+

2

1

3

4

T

T1

P

P1

R

O

5

LAR

4

3

ECR

4

2

3

7

6

8

CC

LAR

ECR

OAT

R

B

(Damper Actuator)

Logic Module

600

150

MAS

ES

+

-

BLK

YEL

WHT

TAN

Ohm

Ohm

VIO

BRN

GRY

YEL

BRN

ORG

BRN

BRN

BRN

BLU

GRY

GRY

BRN

YEL

BLU

BRN

LOC

RED

RED

HP

GRY

GRY

FP1

230V

NOTE 3

ORG

24V

(208V)

CB

BLU

YEL

RED

BLU

SEE

BLK/RED

(460V)

VIO or

or

BLK

NOTE 7

SEE

NOTE 7

SEE

Use copper conductors only.

Refer to Data Plate

Power Supply

WHT

GRN

BLK

Field

Wiring

GFI

(Optional)

115V / 1PH

L

C

Y

O

R

G

Typical T-stat

GRY

BC

BRN

BRN

YEL

BLK

BLK

BLK

BLK

BLK

BLK

(Optional)

Disconnect

CB

OR

BLK

BLK

BLK

Power

Distribution

Block

L3

L1

L2

Blower Motor

BC

Compressor

L3

CC

L1

L2

BLK

BLK

BLK

BLK

BLK

BLK

T2

T3

T1

Ground

L3

L1

L2

Alarm

Common

24 VAC

Fan

Cooling

Compressor

50RTG03-07 WITH ECONOMIZER AND COMPLETE C CONTROLLER

AL

Alarm Relay Contacts

BC

Blower Mtr Contactor

CB

Circuit Breaker

CC

Compressor Contactor

ECR —

Economizer Relay

EH1

Auxiliary Heat Stage 1

EH2

Auxiliary Heat Stage 2

ES

Enthalpy Sensor

FP1

Sensor, Water Coil Freeze Protection

FP2

Sensor, Air Coil Freeze Protection

HP

High Pressure Switch

JW1 —

Jumper, Alarm Mode

LAR —

Low Ambient Relay

LOC —

Loss-of-Charge Pressure Switch

MAS —

Mixed Air Sensor

NEC —

National Electrical Code

OAT

Outside Air Thermostat

PM

Performance Monitor

P1

Field Wiring Terminal Block

RVS — Reversing Valve Solenoid

Relay Contactor Coil

Solenoid Coil

Thermistor

Ground

Field Line Voltage Wiring

Field Low Voltage Wiring

Printed Circuit Trace

LEGEND

NOTES:

1. Compressor and blower motor thermally protected

internally.

2. All wiring to the unit must comply with NEC and

local codes.

3. 208/230 v transformers will be connected for

208 v operations. For 230 v operations, discon-
nect Red lead at L1, and attach Orange lead to
L1. Close open end of Red Lead with insulating
tape.

4. FP1 jumper provides freeze protection for

WATER. When using ANTI-FREEZE solutions, cut
FP1 jumper.

5. Typical thermostat wiring shown. Refer to thermo-

stat Installation Instructions for wiring to the unit.

6. 24 v alarm signal shown. For dry alarm contact,

cut JW1 jumper and dry contact will be available
between AL1 and AL2.

7. Transformer secondary ground via Complete C

board standoffs and screws to control box.
(Ground available from top two standoffs as
shown.)

Fig. 4 — Typical Aquazone™ Complete C Control Wiring