Digital audio connections – 360 Systems Instant Replay DR-554 User Manual

Page 28

Advertising
background image

Page 28

Instant Replay Owner's Manual

Unbalanced connections should be made by connecting the unbalanced signal output to pin 2 of the
Instant Replay and ground to pin 1, with pin 3 left unconnected.

Audio Outputs

The main A

NALOG

O

UTPUTS

are a pair of male XLR-3 connectors. The output is electronically

balanced, and is capable of driving loads of 600 ohms or greater. Full scale output level is +25 dBu
with the O

UTPUT

A

TTENUATOR

in the 0 position. Output cables should be wired the same as shown

above for the inputs.

Unbalanced connections are achieved by connecting pin 2 of the Instant Replay XLR Output to the
unbalanced input and pin 1 to ground, with pin 3 left unconnected.

Output Attenuator Switch

The O

UTPUT

A

TTENUATOR

switch is located on the rear panel. Set this switch to the in position for

operation of Instant Replay with equipment having a nominal operating level of +4 dBu. Set the
switch to the out position for use with equipment operating at -10 dBm.

The switch has no effect on the L

EVEL

M

ETERS

, digital audio outputs, or the H

EADPHONE

O

UTPUT

.

Headphone Output

The H

EADPHONE

O

UTPUT

always carries the same signal as the Main outputs, but its level is

controlled by the H

EADPHONES

L

EVEL

control on the front panel.

When the P

REVIEW

button is activated in Stop mode, the H

EADPHONE

O

UTPUT

is active and the Main

Outputs are turned off during subsequent playback. It may be helpful to use the H

EADPHONE

O

UTPUT

for control room monitoring, while the Main Outputs provide the main feed to a mixer or transmitter.

DIGITAL AUDIO CONNECTIONS

AES/EBU Input

An XLR-3 female connector is provided for digital input in the AES/EBU format. There is a
selectable Sample Rate Converter built in to Instant Replay. When SAMPLE RATE CONVERTER
is ENABLED, the input will accept any sample rate from 24k samples/second to 50k samples/second.
Use only special AES cable having an impedance of 110 ohms. Limit the cable run to 100 feet. Do
not use microphone cables for runs of over 6 feet.

IEC 958 Type II Input

An RCA "phono" connector provides a digital input from consumer or semi-pro equipment. Most
equipment with connectors marked "S/P DIF" can be connected to this input.

As described in the previous section, when SAMPLE RATE CONVERTER is ENABLED the input
will accept any sample rate from 24k samples/second to 50k samples/second. Use only low-
capacitance 75

Ω

coaxial cable, such as those made for video connection between VCRs and

television video inputs. Do not use audio cables with RCA connectors.

Digital Audio Interfacing

Should Instant Replay detect a mismatch at its digital audio ports when preparing to record, the P

LAY

button is disabled and an error message appears in the display. Possible mismatches can include
format conflicts, non-audio data and data flagged as invalid. Copyright Protected data (“SCMS”) will
cause a similar error message. Correct the mismatch as necessary.

Advertising