Fault description

Cause

Remedy

Comminution material is

escaping

Material is extremely fine

Insert sample exhaust system (see Ä Chapter 6.5

‘Sample exhaust system with cyclone separator’

on page 39)

Runs unevenly with strong

vibrations

Rotor imbalance

Cones soiled (see Ä Chapter 6.1.4 ‘Inserting /

changing a rotor’ on page 31)

Bearing in closing lid (6) defec-

tive

Replace bearing

Pieces broken off rotor (3)

Replace rotor (3) (Ä Chapter 6.1.4 ‘Inserting /

changing a rotor’ on page 31)

Rotor and fixed knives are

touching each other (audible

metal contact noise)

Switch device off immediately, disconnect from

mains, check gap widths and correct. Check rotor

and fixed knives for damage. (See

Ä

Chapter 6.1.2 ‘Inserting / changing the fixed

knives’ on page 29)