Fig. 4-62 resume dispense slow display, Slow feed on alarm – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 58

45
CHAPTER 4
Operating Procedures/Dispenser
FIG. 4-61 RESUME DISPENSE SLOW DISPLAY
Slow Feed On Alarm
- - - - - ALARM CONDITION - - - - -
•
If the Slow Dispense Gate valve or feeder
does NOT close or shut off, the SLOW
FEED ON alarm appears on the display.
(See Fig. 4-62)
FIG. 4-62 SLOW FEED ON ALARM
1.
Determine why the Slow Feed is on
and correct the problem.
2.
Press the Clear button to clear the
alarm. The wait timer display appears.
(See Fig. 4-63)
FIG. 4-63 WAIT DISPLAY
•
If the weight is Not within the target win-
dow and you do not have the JOG function
on, the dispense is not accepted in the wait
state and an UNDER DISPENSE or
OVERDISPENSE ALARM appears
depending on the weight dispensed.
Under Dispense/Over Dispense Alarms
- - - - - ALARM CONDITION - - - - -
•
If the target weight is NOT within the tar-
get window and you do not have the JOG
function turned ON, the dispense is not
accepted and an UNDERDISPENSE or
OVERDISPENSE alarm appears depend-
ing on the weight dispensed. (See Fig. 4-
64 & 4-65)
FIG. 4-64 UNDERDISPENSE ALARM
FIG. 4-65 OVERDISPENSE ALARM
•
OVERDISPENSE ALARM, press the
Clear button to clear the alarm. The
Accept the Dispense? display appears.
(See Fig. 4-66) At this time you can:
1. Accept the dispense by pressing the
START button.
2. If your system allows, physically
remove some of the material until it
meets the target window requirements
and then press the START button.
3.
The instrument returns to the Waiting
ON display, repeats the motion check,
autotares and/or checks the OK to
Dispense processes and begins dis-
pense cycle number 2.
NOTE:
Pressing the Stop button returns the display to the
Standby Display. Any further cycles are not com-
pleted.