Fast dispense simultaneous, Ibc dispense alarms, Not ok to dispense alarm – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 76: 46 last cycle in granules sequence, Standby display, Not ok to dispense

63
CHAPTER 5
Operating Procedures/IBC Dispenser
FIG. 5-43 SLOW DISPENSE HOLD
•
To resume Slow dispense press the Start
button.
Fast Dispense Simultaneous
•
Once dispensing begins, the Fast Dispense
Display appears, however both Fast and
Slow dispense operate at the same time.
(See Fig. 5-44)
FIG. 5-44 IBC DISPENSE DISPLAY/FAST DISPENSE
ON
NOTE:
The “Fast Dispense” appears for both Single or
Dual Speed Dispensing.
1.
Once the Fast Dispense reaches a set
point it stops.
2.
The Slow Dispense continues to dis-
pense until the loss-in-weight target
window is reached. (See Fig. 4-45)
FIG. 4-45 IBC DISPENSE DISPLAY/SLOW DISPENSE
ON
3.
If the dispense is within the target
window and you do not have the Dis-
charge Function turned ON (See Dis-
charge Function above), the
instrument returns to the Waiting On
Display, repeats the motion check,
autotares and/or checks the OK to
Dispense processes and begins dis-
pense cycle number 2, then 3, 4 and so
on.
4.
If the dispense is within the target
window and it is the last dispense
cycle (See Fig. 4-46) of a dispense
sequence, the instrument goes to
Standby and the Standby Display
appears. (See Fig. 4-47)
FIG. 4-46 LAST CYCLE IN GRANULES SEQUENCE
FIG. 4-47 STANDBY DISPLAY
IBC Dispense Alarms
Not OK to Dispense Alarm
- - - - - ALARM CONDITION - - - - -
•
If the OK to Dispense function is turned
On and is not present within a pre-pro-
grammed time frame a NOT OK TO DIS-
PENSE appears in the display. (See Fig. 5-
48)
FIG. 5-48 NOT OK TO DISPENSE
1.
The Operator needs to determine why
it is NOT OK to DISPENSE by
checking for problems with the elec-
trical and /or mechanical systems.