Jog stuck on alarm jog count alarm, Discharge alarms, Not ok to discharge alarm – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 81: Did not jog alarm, Jog stuck on alarm, Jog count alarm, 73 jog display/jog continue

Advertising
background image

HI 3010 Filler/Dispenser/IBC

68

User Guide

Filler/Dispenser/IBC is placed in a hold
state. (See Fig. 5-69)

FIG. 5-69 DID NOT JOG ALARM

1.

Check to see why there was no Jog.
Correct the problem. Press on the
Clear button to clear the alarm.

2.

The Jog sequence resumes from
where the Jog left off when it was
paused.

Jog Stuck On Alarm

After each Jog the IBC dispenser goes to a
pause state (Jog OFF) for a pre-determined
period of time if the jog stops. In this state
it checks the weight to see if it is within
the target window. If it is, it moves onto
the next cycle. If it is Not, it jogs again as
long as the allowable number of jogs has
not been exceeded. If the Jog does not stop
the JOG STUCK ON ALARM appears.
(See Fig. 5-70)

FIG. 5-70 JOG STUCK ON ALARM

1.

Check to see why the gate valve or
feeder did not close or stop. Correct
the problem. Press on the Clear button
to clear the alarm.

2.

The instrument goes back to the
WAIT mode where it checks if the
weight is within the target window. If
the weight is still below the target
window the instrument begins another
jog cycle.

Jog Count Alarm

- - - - - ALARM CONDITION - - - - -

If the pre-programmed number of JOG
sequences are completed and an UNDER-
DISPENSE condition still exists, a JOG
count alarm appears telling you that you
have used up the JOGs for this sequence of
cycles. (See Fig. 5-71)

FIG. 5-71 JOG COUNT ALARM

1.

Press the Clear button to clear the
alarm.

2.

The JOG display reappears asking
you if you want to start the JOG
sequence again. (See Fig. 5-72)

FIG. 5-72 JOG DISPLAY/JOG CONTINUE

3.

If you want the instrument to JOG
again, press the Start button to repeat
the JOG sequence.

4.

If you DO NOT want the instrument
to JOG again, press the Stop button.
The instrument goes to the Standby
Menu and doesn’t complete any more
cycles.

Discharge Alarms

Not OK to Discharge Alarm

- - - - - ALARM CONDITION - - - - -

If the function is on and instrument does
not see an OK to Discharge, a Not OK to
discharge alarm appears. (See Fig. 5-73)

Advertising