Pausing the jog cycle, Discharge function, Ay fig. 5 – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 74: Discharge diagram

61
CHAPTER 5
Operating Procedures/IBC Dispenser
FIG. 5-34 JOG 1 DISPLAY
Step 3. The instrument goes to the Jog Off State where it
checks to see if the loss in weight is within the tar-
get window. A timer is displayed counting down the
time the instrument is in the Jog Off state. If it is,
the dispense process continues going through the
dispense cycles until all cycles are complete. (See
Fig. 5-35)
FIG. 5-35 JOG DISPLAY/COMPLETED FOUR JOG
SEQUENCES/CHECKING WEIGHT
Pausing the Jog Cycle
•
You can pause the JOG cycle by pushing
the Stop button once at any time during the
JOG cycle. The JOG Hold display
appears. (See Fig. 5-36)
FIG. 5-36 JOG PAUSED 1.50 SECONDS INTO THE
JOG SEQUENCE
Step 4. If the loss in weight is still NOT within the target
window, the instrument automatically continues
through the preset JOG sequences until the target
window is reached.
NOTE:
To prevent Jogging make sure you turn the Auto
Pre-Act ON. It is important to note that if Auto
Preact is ON, the Filler/Dispenser will automati-
cally adjust the Ingredient Pre-Act parameter
insuring that “UNDERDISPENSE” and “OVER-
DISPENSE” conditions do not occur. The new
Pre Act value is saved for the ingredient being
dispensed and becomes part of the Ingredient
Parameter. It is highly recommended that you
turn the Auto Pre-Act function ON. (For configu-
ration information see the HI 3010 Service Man-
ual for instructions)
Discharge Function
After an IBC Dispense completes, which may include a JOG
if necessary, you have the option to Discharge the Dispense.
Once the instrument has determined that the dispense is
within the target window, it discharges before returning to
the Dispense ON Display or the Dispense Standby Display
depending on which dispense cycle you just finished.
NOTE:
You are not discharging the IBC Dispenser vessel
but the receiving container. (See Fig. 5-37)
FIG. 5-37 DISCHARGE DIAGRAM
The Auto Discharge Function is user selectable and must be
turned ON during Setup. (To turn the Auto Discharge Func-
tion ON, see the HI 3010 Service Manual for instructions)
Step 1.
The Filler/Dispenser/IBC then gets set to Dis-
charge the material in the receiving container.
The Awaiting Command to Discharge display
appears if auto discharge is Off but discharge is
On. (See Fig. 5-38) To start the discharge push
the Start button. The Command to discharge can
also come from a PLC or other controller.