Jog stuck on alarm jog count alarm, Discharge alarms, Not ok to discharge alarm – Hardy HI 3010 Filler/Dispenser Controller User Manual

Page 60: Fig. 4-72 to jog again press start display, 73 jog stuck on alarm, 74 jog count alarm, 75 jog display/jog continue

Advertising
background image

47

CHAPTER 4
Operating Procedures/Dispenser

FIG. 4-71 TO JOG AGAIN PRESS START DISPLAY

2.

The Jog sequence resumes from
where the Jog left off when it was
paused.

Jog Stuck On Alarm

- - - - - ALARM CONDITION - - - - -

After each Jog the instrument goes to a
pause state (Jog Off) for a pre-determined
period of time if the Jog stops. In this state
it checks the weight to see if it is within
the target window. If it is the instruments
moves to the next cycle. If if is not is jogs
again as long as the allowable number of
jogs has not been exceeded. If the Jog does
not stop the JOG STUCK ON ALARM
appears. (See Fig. 4-72)

FIG. 4-72 JOG STUCK ON ALARM

1.

Check to see why the gate valve or
feeder did not close or stop. Correct
the problem. Press the Clear button to
clear the alarm.

2.

The instrument goes back to the
WAIT mode where it checks if the
weight is within the target window. If
it is still under the minimum target
weight the instruments begins another
jog cycle.

Jog Count Alarm

- - - - - ALARM CONDITION - - - - -

If the JOG sequences are completed and
an UNDERDISPENSE condition still
exists, a JOG count alarm appears telling

you that you have used up the JOGs for
this sequence of cycles. (See Fig. 4-73)

FIG. 4-73 JOG COUNT ALARM

1.

Press the Clear button to clear the
alarm.

2.

The JOG display reappears asking
you if you want to start the JOG
sequence again. (See Fig. 4-74)

FIG. 4-74 JOG DISPLAY/JOG CONTINUE

3.

If you want the instrument to JOG
again, press the Start button to repeat
the JOG sequence.

4.

If you DO NOT want the instrument
to JOG again, press the Stop button.
The instrument goes to the Standby
Menu if the JOG and does not com-
plete any more cycles.

Discharge Alarms

Not OK to Discharge Alarm

- - - - - ALARM CONDITION - - - - -

If the function is on and instrument does
not see an OK to Discharge, a Not OK to
discharge alarm appears. (See Fig. 4-75)

FIG. 4-75 NOT OK TO DISCHARGE ALARM

Advertising