Support legs are designed for 130 mph wind or Universal Building

Code seismic zone 4 loading, and are available for hopper clearances

of 4, 6, 8, and 10 ft. Up to five modules may be bolted together

and supported by one set of 4 legs. Standard design is for 4 ft.

hopper clearance.
The standard Millennium is supplied with a pyramid style hopper.

A trough style hopper is available as an option. Pyramid hoppers

have a minimum side slope of 60 degrees and a flanged outlet of

12" x 12" with a drilling that matches an optional Rotary Lock. The

trough hoppers have a 10" wide opening with drilled flanges for

conveyor mounting. Both types of hoppers have quick release lift-off

access doors.
The outlet plenum can be either open to roof top access or

walk-in style. Outlets may be located at either end of the plenum,

and have a 2'-1" x 8'-4" opening with a standard drilling as shown

on the drawings.

2.0 General Description

The Millennium is a modular, continuous, automatic, self-cleaning,

fabric pulse-jet dust collector. The standard module is an open top

design. Flanges inside the roof top doors prevent water from leaking

into the housing. The access doors are lift-off type. Each size 96

module has two doors; while the size 144 module has three doors.

The walk-in plenum design will have one 20” x 60” access door

opening at one end of the unit, opposite the air discharge opening.

Handrails and ladders are supplied with both plenum types. An

optional air and solenoid valve service platform is available. The

access ladder is selected to accommodate both bag length and

hopper clearance. On a standard roof top access unit, using a 12 ft.

bag with a 10 ft. hopper clearance, or a 14 ft. bag with either an 8 or

10 ft. hopper clearance, the access ladder is supplied in two sections

with an intermediate platform, to comply with OSHA regulations.
The cleaning cycle is controlled by a solid-state timer located in a

NEMA 4 enclosure. The timer control can be field adjusted for proper

operation. (See Bulletin E-97)
All modules are constructed with a 6" diameter surge tank

(compressed air manifold) which is fitted with 1

1 2

" diaphragm pulse

valves. Pulse valves are connected to solenoid pilot valves with

plastic tubing on standard units, and with metal tubing on high

temperature units. See figure 3 for details of the compressed air surge

3

1.4 The Millennium - A Description

The standard Millennium collector comes in 14 basic sizes. The size

variations are composed of combinations of either 96 bag or 144 bag

modules, with one to five modules per unit. The Millennium will use

5

1 4

" diameter bags in a 7" x 7" spacing pattern. Bag lengths of 8, 10,

12, and 14 ft. are available.
Standard module combinations are listed below. The 96 bag modules

are indicated as “96” and the 144 bag modules as “144”. The letter

designation refers to the diagram shown above in Figure 2.

There is no limit to the size collector that can be supplied.

However, any arrangements exceeding the combinations listed

above will require intermediate support legs and additional outlets

in order to maintain acceptable airflow velocities. See contract

drawings for details.
The modular design will permit an existing Millennium system to

be expanded with no significant disruption to the operating unit(s).
Housings, hoppers, plenums, and tube sheets are made of 10 ga.

carbon steel. Modules are available for -20" and -30" w.g. plenum

pressure, and for temperatures of 180, 270, and 400 degrees

Fahrenheit. Consult the P.O. and submittal documents to verify

which version you have.

Size

Module Arrangement

96

D96

144

D144

192

A96 + C96

240

A96 + C144

288

A144 + C144

336

A96 + B96 + C144

384

A96 + B144 + C144

432

A144 + B144 + C144

480

A96 + B96 + B144 + C144

528

A96 + B144 + B144 + C144

576

A144 + B144 + B144 + C144

624

A96 + B96 + B144 + B144 + C144

672

A96 + B144 + B144 + B144 + C144

720

A144 + B144 + B144 + B144 + C144

Figure 2

Alt.

Outlet

Alt.

Outlet

Std.

Outlet

Std.

Outlet

A

B

B

B

C

D

Inlets

Inlet

Advertising