7 btu transmitter assembly, Figure 6.3, Btu transmitter pump disassembly – AERCO KC1000 Water Heater July 2011 User Manual

Page 48: Maintenance

Advertising
background image

MAINTENANCE

6-4

6.7 BTU TRANSMITTER ASSEMBLY

The BTU Transmitter is a crucial part of the unit’s temperature control system. It must be inspected and

kept free of scale and debris in order for the unit to maintain accurate outlet water temperatures.

To inspect the transmitter:

1. Place the

ON/OFF switch in the OFF position.

2. Remove the sheet metal side panels and hood from the unit.

3. Shut the water inlet, outlet and recirculation valves to the unit.

4. Open the drain valve on the unit.

5. Slowly open the pressure relief valve to allow air-flow into the unit.

6. Fully drain the unit.

7. Disconnect electrical power from the unit.

8. Remove the 4 screws holding the BTU transmitter pump to the impeller housing. Remove and set the

pump aside, (See Fig. 6.3).

NOTE:

It is not necessary to disconnect the electrical wires to the pump.

Figure 6.3

BTU Transmitter Pump Disassembly


9. Using a 5/8” and 9/16” wrench, loosen the 4 compression fittings holding the lower tubing assembly in

place, (See Fig. 6.4).

Advertising