CONTROL PANEL OPERATING PROCEDURES

3-8

(a) Blower relay energizes and turns on

blower.

(b) Air/Fuel Valve rotates to the full-open

purge position and closes purge position
switch. The dial on the Air/Fuel Valve
(Figure 3-4) will read 100 to indicate that
the valve is full-open (100%).

(c) The

FIRE R ATE bargraph will show

100%.

STEPPER

MOTOR

DETAIL "A"

DIAL
(DETAIL “A”)

100

BLOWER

BURNER

Figure 3-4.

Air/Fuel Valve In Purge Position

4. Next, the blower proof switch (Figure 3-5)

closes and the display will show Purging

and

indicate the elapsed time of the purge cycle
in seconds. The normal (default) time for the
purge cycle is 7 seconds.

154

155

AIR/FUEL VALVE

BLOWER PROOF

SWITCH

TO FRAME

HARNESS

Figure 3-5.

Blower Proof Switch

5. Upon completion of the purge cycle, the

Control Box initiates an ignition cycle and the
following events occur:

(a) The Air/Fuel Valve rotates to the low-fire

ignition position and closes the ignition
switch. The dial on the Air/Fuel Valve
(Figure 3-6) will read between 25 and 35
to indicate that the valve is in the low-
fire position.

(b) The igniter relay is activated and pro-

vides ignition spark.

(c) The gas Safety Shut Off Valve (SSOV)

is energized (opened) allowing gas to
flow into the Air/Fuel Valve.

6. Up to 7 seconds will be allowed for ignition to

be detected. The igniter relay will be turned
off one second after flame is detected.

7. After 2 seconds of continuous flame, Flame

Proven

will be displayed and the flame

strength will be indicated. After 5 seconds,
the current date and time will be displayed in
place of the flame strength.