Aerco, Appendix e, Ap-a-804 – AERCO KC1000 Heater 2002 User Manual
Page 86
APPENDIX E
E-2
18(45.7)
49 (124.5)
57 (144.8)
16-3/4
22-5/8
71-7/8
71-7/8
19 (48)
15-1/2 (39.4)
6 (15.2) I.D.
FLUE CONN.
3/4 (1.9) DIA.
(ENCLOSURE)
PRESS./TEMP.
RELIEF
2" NPT HOT
2" NPT COLD
3-1/8 (7.9)
(182.6)
5-3/4 (14.6)
REMOTE ALARM & CONTROL
CONNECTION - 3/4 CONDUIT
1-1/4 NPT GAS INLET
(182.6)
(57.5)
(42.5)
LIFTING LUG
VALVE
1"NPT
DRAIN
VALVE
5/8" I.D.
MALE HOSE
CONDENSATE
DRAIN
2"NPT
RECIRC
CONN.
1) ALL DIMENSIONS SHOWN ARE IN INCHES (CENTIMETERS)
AP-A-804
NOTES:
POTABLE WATER HEATER
INTERNATIONAL INC.
1:24
P.K./G.K.
DATE
DWN BY
SIZE
SCALE
APPD
CHKD
B
WATER OUTLET
WATER INLET
29
3 (8)
c.g.
INLET ADAPTER
COMB. AIR INTAKE
AERCO
NORTHVALE, NEW JERSEY 07647
MODEL KC1000 GAS FIRED
22-1/4 (57)
47 (119.4)
22 (56)
(FLOOR FLANGE)
2) DRAIN VALVE & RELIEF VALVE ARE INCLUDED SEPARATELY IN SHIPMENT
A
2-1-95
DIMENSIONAL DRAWING
AC SERVICE C0NN.
3/4 CONDUIT
120VAC SINGLE PHASE
20 AMP W/GRD
35 (89)
TYP.
4-PLCS
(
)
c.g.
78-1/2
(199.4)
13-9/16
(34.4)
3/4" NPT GAS VENT
CONN. FOR "IRI GAS
TRAIN OPTION" ONLY
(OPTIONAL O.A.
AVAIL. - 6" OD)
HEAT EXCHANGER DESIGN STANDARDS
MAXIMUM
TEMP. (°F)
ASME B & PV CODE SECTION IV STAMP HLW
SHELL SIDE
PRESS. (PSIG)
155
MAX. WORKING
TEST PRESS.
(PSIG)
210
233
REV.