LoGGInG on And oFF.

To prevent unauthorized programming of the 11-65000 when using a PC or terminal, it is necessary to enter a
password at the beginning of every programming session. When communications are first established with the
ENTRACOMP® 28SA-Plus, the screen will say:

weLCoMe to entrACoMP® 28SA-Plus

enter PASSword:

The default password is “12345”. When you begin your first programming session, enter “12345” and press the “ENTER”
key when the password is requested. The main menu will then be displayed.
During this first programming session, use the “Password” menu selection of the System Settings Menu to set a
password of your choice. You may change your password at any time using the “Password” selection of the menu. It
is not necessary to set or use a password when programming your unit with the Program Deck.
Note that when using Secura Key’s SK-NET TM software, it is recommended that when you change the password
you do so from the location properties while connected to the 28SA-Plus. A separate manual is included with the
SK-NETTM software.
If you should forget your password, you must turn off the power to the unit. Then, while holding in the reset button
(see Figure 1), turn the power back on. This will reset the password to “12345.” This same procedure also re-calibrates
the sensors in the reader, so be sure there is no magnetism near the reader (i.e., a card) when the password is being
reset. Wait for the red/green flashing LED to time out (stop blinking) before putting cards on the TOUCH CARD®
reader plate. This procedure should be done with the unit at average operating temperatures; not in extreme heat
or cold.
When the reader is connected to a PC or data terminal, the reader will automatically logoff after four minutes with
no keyboard activity. You will then be required to enter the password again to access the system. Automatic logoff
occurs while in any menu or sub-menu except when displaying current transactions. It is advisable to exit the system
when you are finished by using the “Logoff” selection of the main menu.

ProGrAMMInG wItH ProGrAM CArdS

There are two kinds of cards used with the 1-65000: Access Cards and Program Cards. Access Cards are used by
individuals to gain access to the passageway. Program Cards are used to tell the ENTRACOMP® 28SA-Plus what to
do.

the Program Cards are as follows:

“0”

ZERO

“1”

ONE

“2”

TWO

“3”

THREE

“4”

FOUR

“5”

FIVE

“6”

SIX

“7”

SEVEN

“8”

EIGHT

“9”

NINE

“*”

THRU

“VALID”

VALIDATE

“VOID”

VOID OR CANCEL

“SET TIMER”

SET LATCH, ANTIPASSBACK TIMER, TIME/DATE

“ACTIVE/INACTIVE”

ACTIVATE OR INACTIVATE SYSTEM