Flushing the system, Preparing unit for storage or shipment, Preparing system for storage – AXEON R2-Series User Manual

Page 25: Preparing unit for shipment

Advertising
background image

25

R2-Series User’s Manual

11/13/12

MKTF - 212

FLUSHING THE SYSTEM

The system should be flushed weekly to remove sediment from the surface of the membranes. To
manually flush the system, follow the preceding steps:

1.

The system must be operating during the flush procedure.

2.

Fully open the concentrate valve. (Figure 1B, Page. 15)

3.

Allow the system to run for 10 to 20 minutes.

4.

After 10 to 20 minutes, close the concentrate valve to its previous setting. Ensure the proper
concentrate flow rate is going to the drain.

5.

The system is now ready to operate.

PREPARING UNIT FOR STORAGE OR SHIPMENT

PRIOR TO SHIPPING OR STORING YOUR SYSTEM, THE SYSTEM SHOULD BE CLEANED

WITH AN APPROPRIATE CLEANER, FLUSHED WITH WATER, AND PROTECTED FROM
BIOLOGICAL ATTACK WITH AN APPROPRIATE SOLUTION FOR MEMBRANE ELEMENTS. THE
MEMBRANE HOUSING(S) AND PLUMBING LINES OF THE SYSTEM MUST BE COMPLETELY
DRAINED. ANY WATER REMAINING IN THE PLUMBING OF A SYSTEM MAY FREEZE, CAUSING
SERIOUS DAMAGE.

PREPARING SYSTEM FOR STORAGE:

1.

Totally immerse the elements in the membrane housing in a solution of 2% membrane
preservative, venting the air outside of the pressure vessels. Use the overflow technique:
circulate the Memstor solution in such a way that the remaining air in the system is minimized
after the recirculation is completed. After the pressure vessel is filled, the Memstor solution
should be allowed to overflow through an opening located higher than the upper end of the
highest pressure vessel being filled.

2.

Separate the preservation solution from the air outside by closing all valves.

3.

Repeat this process at least once a month.

During the shutdown period, the plant must be kept frost-free, or the temperature must not exceed 113°F
(45°C).

PREPARING UNIT FOR SHIPMENT:

4.

Disconnect the inlet, concentrate, pre-filter, and permeate plumbing.

5.

Drain all water from the pre-filter cartridge housings by unscrewing the housings, removing the
pre-filter cartridges, and drain the water from the housings.

6.

Disconnect the tubing from the connectors on the permeate and concentrate inlets and outlets.