The amount of permeate water recovered for us
and % rejection, use the following formula

% Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100

% Rejection = (Feed TDS

NOTE: ALL FLOW RATES MUST BE EXPRESSED IN THE SAME UNITS

SYSTEM REQUIREMENTS

PLUMBING

The membranes and high pressure pumps used on R
continuous flow of water with a minimum

FEED WATER CONNECTION

1. Locate the 1” FNPT Sole

(Figure 1A, Page 13)

2.

Attach the inlet piping to the 1

PERMEATE (PRODUCT WATER) CONNECTION

Locate the 1” or 3/4” connection (d
Ensure that the permeate water can flow freely
irreversible damage to the membrane elements.
be run to the holding tank with PVC fittings, or other FDA approved materials
being used does not leach into the permeate water.

CAUTION: THE PH OF THE REVERSE O

BE 1-2 PH UNITS LOWER THAN THE FEED WATER PH.

A LOW PH CAN

PLUMBING MATERIALS SUCH AS COPPER PIPING.

CONCENTRATE (WASTE WATER)

6

Series User’s Manual

water recovered for use is expressed as a percentage. To calculate % recovery

following formulas:

% Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100

Example:

25% = (1.04/4.04) x 100

% Rejection = (Feed TDS – Product TDS)/(Feed TDS) x 100

Example:

99.2% = [(10,000-80)/10,000] x 100

NOTE: ALL FLOW RATES MUST BE EXPRESSED IN THE SAME UNITS.

SYSTEM REQUIREMENTS AND OPERATION GUIDELINES

gh pressure pumps used on R2-Series Reverse Osmosis Sy

us flow of water with a minimum feed pressure of 45 psi, not to exceed 85

FEED WATER CONNECTION

” FNPT Solenoid Valve feed water inlet.

tach the inlet piping to the 1” FNPT Solenoid Valve feed water inlet.

PERMEATE (PRODUCT WATER) CONNECTION

1” or 3/4” connection (depending on the unit) labeled permeate and attach to

sure that the permeate water can flow freely with no backpressure. Backpressure can cause

damage to the membrane elements. The 1” or 3/4” (depending on the unit)

with PVC fittings, or other FDA approved materials. This is so

into the permeate water.

H OF THE REVERSE OSMOSIS PERMEATE WATER WILL TYPICA

LOWER THAN THE FEED WATER PH.

A LOW PH CAN

PLUMBING MATERIALS SUCH AS COPPER PIPING.

CONCENTRATE (WASTE WATER) CONNECTION

11/13/12

e is expressed as a percentage. To calculate % recovery

% Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100

x 100

OPERATION GUIDELINES

Reverse Osmosis Systems require a

exceed 85°F.

labeled permeate and attach to the storage tank.

Backpressure can cause

epending on the unit) permeate line can

This is so that the material

SMOSIS PERMEATE WATER WILL TYPICALLY

LOWER THAN THE FEED WATER PH.

A LOW PH CAN DAMAGE CERTAIN