SPECIFICATIONS

Dimensions: 4-3/4" dia. X 2-3/16" deep.
Weight: 1 lb. 2 oz.
Finish: Baked dark gray enamel.
Connections: 1/8 N.P.T high and low pressure

taps, duplicated, one pair side and one
pair back.

Accuracy: Plus or minus 2% of full scale, at

70° F. (Model 2000-0, 3%; 2000-00, 4%).

Pressure Rating: 15 PSI.
Ambient Temperature Range: 20° to 140° F
Standard gage accessories include two 1/8"

N.P.T. plugs for duplicate pressure taps,
two 1/8" pipe thread to rubber tubing
adapters, and three flush mounting
adapters with screws.

Caution: For use with air or compatible gases

only.

For repeated over-ranging or high cycle rates,

contact factory.

Hydrogen Gas Precautionary Note: The rec-

tangular rare earth magnet used in the
standard gage may not be suitable for
use with hydrogen gas since a toxic and
explosive gas may form. For hydrogen
service, consult the factory for an alter-
nate gage construction.