Storage Recommendations (continued)


Isolation Dampers

• All limit switches, solenoids, and air cylinder ports must be capped and

taped to prevent any moisture or dirt from entering.

• Equipment can sit outside provided it is covered with a tarp and is on a

pallet or skid to keep it out of water and dirt.


Rotary Valve

• Rotor and interior of valve should be well oiled with vegetable oil to

prevent rust and to maintain compatibility with product.

• Unit can be stored outside provided it is covered with a tarp and is on a

pallet or skid to keep it out of water and dirt.

• Reference rotary valve IOM manual for long-term storage.


Butterfly (Wafer Valve)

• All limit switches, solenoids, and air cylinder ports must be capped and

taped to prevent any moisture or dirt from entering.

• Unit can be stored outside provided it is covered with a tarp and is on a

pallet or skid to keep it out of water, dirt and sunlight.

• Reference butterfly valve IOM manual for long-term storage.


Level Indicators

• Store these items inside a protected cool dry area.


AC Inverters

• Store these items and all other electrical controls inside a protected cool

dry area.