CAMCORP CAM-AIRO Vertical Cartridge User Manual

Page 42

Advertising
background image

CAMCORP, INC.

Phone: 913-831-0740 Fax: 913-831-9271

www.camcorpinc.com

0 +95 .)

( ) %+.

55

03

+ 24

Chemical attack

Filter material degrades due to attack from certain chemicals in the dust

or gasses in the air stream.

High moisture

High moisture content in the collector may cause certain filter cartridge

material to shrink, degrade (more rapidly at elevated temperatures) or

blind off.

Localized abrasion

Abrasion of the filter cartridges where high velocity dusty air hits the filter

cartridges. A dust impingement baffle may be required

to be installed on

the inlet of the dust collector.

0 +95 .)

( )

- 0

Check for mechanical damage.

If the “Power On” indicator is not on, check for proper power input. The

“hot” line connection must be connected to terminal “L1”, as this is the

fused terminal.

Check for a blown fuse; if replacement is necessary, use only 3 AMP

standard 3AG fuse (1-1/4” long). Do not use a slow-blow type fuse.

Check the wiring from the timer to the solenoids for open or short

circuits.

After performing the steps above, if the timer is still not functioning

properly (no output voltage, sequencing problems, etc.) please contact

your CAMCORP representative.