Section 7 – Routine Maintenance

Inspection

Frequency will vary as widely as there are operating conditions. In

general proceed as follows:

Daily – Check unit differential pressure.

Weekly – Check pulse timer board and solenoid valves for function.

This usually is only listening to verify uniform time in intervals between

blasts.

Monthly – Lubricate fan, rotary valve and screw conveyor. Check seals

on latter two for dust loss.

Repairs

Filter cartridges – Generally replacement, although some applications

can be laundered.

Solenoid Valves – Repair kits are available if a valve is stuck open or

fails to operate.

Diaphragm Valves – Repair kits are available if a valve is stuck open or

fails to operate due to a ruptured diaphragm.

Rotary Valves – Usually a matter of periodic seal and blade

replacement. More detailed information is supplied with the valve.

Screw Conveyors – Periodic replacement of “V” belts and shaft seals.

Inspect hanger bearings during filter bag change. Failure will be

detected by the squeal.

Fans – “V” belt tension and replacement of bearings if running rough.

Make sure rotor balance is maintained.