THERMAL CUT-OFF (Electric Models Only)

The thermal cut-off is located on the side of the heater element housing.

To test the thermal cut-off, set the resistance scale to Rx1 and place the probes on the terminals with
the red wires. The meter should read continuity, (0) ohms resistance. This is because this thermal cut­

off is normally closed and will open at temperatures above 350“ R If the thermal cut-off is open {infinite

resistance) it must be replaced.

THERMAL CUT-C

MOT MESETTAB

3SO-F

heater

11.2* 1!S.^

ELECTRIC HEATING ELEMENT

To test the electric heating element, set the resistance scale to Rx1 and place the probes on the
terminals with the red/white and red wires. The meter should read between eleven and 16 ohms

resistance.

OPERATING

thermostat

150"F OR ISS'-F RR