H 3-wire conduit installation, H 4-wire conduit installation, Installation instructions – GE CS975SDSS User Manual

Page 44

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions

H 3-WIRE CONDUIT INSTALLATION

Loosen the 3 lower terminal screws from

the terminal block. Insert the center bare wire
(white/neutral) tip through the bottom center
terminal block opening. On certain models,
the wire will need to be inserted through
the ground strap opening and then into the

bottom center block opening. Insert the two side
bare wire tips into the lower Ie1^ and the lower
right terminal block openings. Tighten the screws
until the wire is firmly secure (approximately
20 inch-lbs.).

NOTE: ALUMINUM WIRING:

Aluminum building wire may be used but it

must be rated for the correct amperage and

voltage to make connection. Connect wires
according to this Step 5 or Step 7 depending
on number of wires.

Terminal

block

Wire tipS'

Brocket

Conduit

Wire used, location and enclosure of splices,
etc., must conform to good wiring practices
and local codes.

E Skip to Step 8 and proceed with the

installation.

H 4-WIRE CONDUIT INSTALLATION

E Loosen the three lower terminal screws from

the terminal block. Remove the ground screw
and ground plate and retain them.

Cut and

discard the ground strap. DO NOT DISCARD
ANY SCREWS.

E Insert the ground bare wire tip between the range

frame and the ground plate (removed earlier) and
secure it in place with the ground screw (removed
earlier). Insert the bare wire (white/neutral) tip
through the bottom center of the terminal block
opening. Insert the two side bare wire tips into
the lower lel^and the lower right terminal block
openings. Tighten the screws until the wire is firmly
secure (approximately 20 inch-lbs.).

Before

^11 ^ Ground strap

Terminal

block

Ground strop

Af^er

Terminal'

block

Wire tips

Ground
screw

Ground plate
(grounding
to range)

Brocket

Wire used, location and enclosure of splices,
etc., must conform to good wiring practices
and local codes.

E Proceed to Step 8.