Alarm card connection guidelines, The router is equipped with two alarm cards, Figure 2-17 alarm card connector location – Cisco XR 12416 User Manual

Page 33: Caution

Advertising
background image

2-33

Cisco XR 12416 and Cisco XR 12816 Router Chassis Installation Guide

OL-17440-01

Chapter 2 Preparing for Installation

Alarm Card Connection Guidelines

Alarm Card Connection Guidelines

The router is equipped with two alarm cards:

One alarm card occupies the dedicated far left slot in the upper card cage

The second alarm card occupies the dedicated far right slot in the lower card
cage

Each alarm card has one 25-pin D-subconnector (ALARM) on the front panel that
connects the router to an external site alarm maintenance system (

Figure 2-17

).

When a critical, major, or minor alarm is generated, it energizes the alarm relays
on the alarm card to activate the external site alarm.

Figure 2-17

Alarm Card Connector Location

The alarm relay contacts on the alarm card consist of standard common, normally
open
, and normally closed relay contacts that are wired to the pins on the
connectors.

Caution

Only safety extra-low voltage (SELV) circuits can be connected to the alarm
connector. Maximum rating for the alarm circuit is 2 A, 50 VA.

ACO/L

T

ALARM

CSC

0

FA

IL

1

0

1

2

ENABLED

ENABLED

FA

IL

CRITICAL

MAJORMINOR

SFC

ALARM

26867

Pin 25

Audio alarm

cutoff switch

Pin 1

Handle

Critical, major, and

minor alarm LEDs

Clock and scheduler card

and switch fabric card LEDs

ENABLED

FAIL

CSC

0

FAIL

1

0

1

2

ENABLED

CRITICAL

MAJORMINOR

SFC

Advertising