Cisco XR 12416 User Manual

Page 34

Advertising
background image

Chapter 2 Preparing for Installation

Alarm Card Connection Guidelines

2-34

Cisco XR 12416 and Cisco XR 12816 Router Chassis Installation Guide

OL-17440-01

Note

To comply with the intrabuilding lightning surge requirements of
GR-1089-CORE, Issue II, Revision 01, February 1999, you must use a shielded
cable when connecting to the external alarm ports on the alarm card. The shielded
cable is terminated by shielded connectors on both ends, with the cable shield
material tied to both connectors.

Table 2-7

lists the pin-to-signal correspondence between the cable connector pins

and the alarm card relay contacts.

Table 2-7

Alarm Connector Pinout

Pin Group

Common

Normally Open

Normally Closed

Critical audible alarm

2

1

14

Major audible alarm

16

3

15

Minor audible alarm

5

4

17

Critical visual alarm

19

6

18

Major visual alarm

8

7

20

Minor visual alarm

22

9

21

Alarm input

13

25