Cisco Nexus 5000 Series Hardware Installation Guide

OL-15902-01

Chapter 1 Cisco Nexus 5500 Platform Overview

Cisco Nexus 5548P Switch

Power Supplies

The Cisco Nexus 5548 switch uses a front-end power supply. The chassis has slots for two power
supplies. Two power supplies can be used for redundancy, but the Cisco Nexus 5548 switch is fully
functional with one power supply.

Figure 1-10

shows the power supply, which has two LEDs: one for

power status and one for failure condition.

Figure 1-10

Power Supply for the Cisco Nexus 5548 Switch

Table 1-1

table lists the LED descriptions for the two power supplies.

If you have one power supply is installed in the chassis, but the other power supply slot is empty,you
should use a blank fller panel to cover the empty slot. See

Figure 1-11

1

Amber fail LED indicates a failure condition. 2

Green power LED indicates the power status.

236710

Table 1-1

Power Supply LED Descriptions

Power Supply Condition

Power LED Status

Fail LED Status

No AC power to all power supplies.

Off

Off

Power supply failure, including overvoltage, overcurrent,
overtemperature, and fan failure.

Off

On

Power supply warning events where the power supply
continues to operate. These events include high
temperature, high power, and slow fan.

Off

Blinking

AC present, 3.3 voltage standby (VSB) on, and the power
supply unit is off.

Blinking

Off

Power supply on and OK.

On

Off