NOTE

Loosen (Do Not Remowe) Terminal Block Screws.
Limit Switch adjustments and securing the Wires

will be done later.

F

Lay Wires in channel on top of Rail and secure with Wire Clips

(Figure 14).

G

Coil and bundle excess Limit Switch Wires on top of Power

Head with Twist Ties. Leave just enough Wire to reach

Terminals on back of Power Head

(Figure 14).

H

Turn Opener upside down, and connect Limit Switch Wires to

Power Head Terminal Block

(Figure 15):

Terminal 4:

OPEN Limit Switch Wire (white).

Terminal 5:

OPEN Limit Switch Wire (white) and

CLOSE Limit Switch Wire (brown).

Terminal 6:

CLOSE Limit Switch Wire (brown).

Figure 15

Connect Limit Switch Wires to Power

Head Terminal Block

C

D

Tie overhand knot at one end of Emergency Release Cord.

Thread opposite end of Cord through Knob and hole in

Magnetic Carriage Assembly Release Lever

(Figure 16).

Tie overhand knot at this end of Emergency Release Cord.

Attach Emergency Release Tag to Magnetic Carriage
Assembly Release Lever.

Please note the following information so it is available if you need

to call us:

Date purchased:

____

Serial number

(Figure 17):

Model number

(Figure 17):

Dealer Name:

Dealer Address:

City:

State:

Zip:

Phone:

/

/

NOTE

Please keep original or photocopy of your sales receipt with

this manual for future reference should service ever be

required.

Figure 17

Model and Serial Numbers