Genie Excelerator User Manual

Page 28

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Problem

Opener does not run
from Remote Control

Door Opener starts

for no apparent reason

Door starts down, then
stops before it is

I

completely closed

I

Door starts down, then
stops and goes back up

Door will only run closed

Door will only run open

Lights will not turn off

Door starts up, but stops
before it is
completely open

Operator runs, but door
does not move

Wall Console Vacation
Lock function does
not work

What

To

Do

1.

Check power source.

A. If Opener is connected to an outlet:

• Plug a working lamp into outlet used for Power Head.
• If lamp glows, power source and outlet are OK.
• If not, check fuse or circuit breaker or non-compatible

GFCI.

NOTE: A

licensed

electrician must replace non-compatible GFCI's.

B. If Opener is connected to a wiring box:

• Check fuse is not blown, or circuit breaker is "Closed" (not tripped).
• If still no power, have a licensed electrician check circuit and wiring.

2.

If power is OK:

• Check connections at Power Head Terminals (see Wall Console Installation page 18), tightening any

loose connections.

Have a Genie Factory Authorized Dealer check that Ribbon Cable between Controller Board and Motor Drive
Board is properly connected to Connectors on Circuit Boards,or call Customer Service at

1-800-35-GENIE.

Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires).
Replace any shorting Staples and shorted Wires.
Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver's memory
and reprogram for remaining remote controls. (See Erase All Receiver Memory on page 22).
Ensure that no Buttons are stuck"pushed-in"on Wall Console or any Remote Controls.

Check Close Limit Switch setting (see Set Limit Switches and Force Controls on page 20).
Adjust as needed.
Check for shorted Wires.
Check garage door for binding.

If a new installation, check Door Arm position.
Check operation of Contact Reverse function.
Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses.
Check Safe-T-Beam® System diagnostic code.
Check Close Force adjustment (see Set Limit Switches and Force Controls on page 20). Adjust as needed.
Check garage door for binding.

Check Open Limit Switch for a short circuit and for proper wiring.
Check Open Force adjustment (see Set Limit Switches and Force Controls on page 20). Adjust as needed.
Check condition of garage door and doorspring(s).

: If you suspect

a

problem with the garage door hardware or springs, contact a Genie

Factory Authorized De aler for service, or contact Customer Service at 1-800-35-GENIE.

Check Safe-T-Beam® System as detailed in the Safe-T-Beam® System Self-diagnosticTroubleshooting Chart
(see Safe-T-Beam® System Self-diagnosticTroubleshooting Section on page 26).
Check Close Limit Switch for a short circuit and for proper wiring.
Check Close Force adjustment (see Set Limit Switches and Force Controls on page 20). Adjust as needed.

Disconnect Wires connecting Wall Console to Power Head (see Wall Console Installation on page 18).
Check their condition and either replace or reconnect.
Until a replacement Wall Console can be obtained,disconnectWall Console and use only Remote Controls
or Wireless Keypad to operate Opener.

Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly
balanced as detailed in Maintenance Section.

liCî: If you suspect a problem with the garage door hardware or springs, contact a Genie

Factory Authorized De aler for service, or contact Customer Service at 1-800-35-GENIE.

Check Open Limit Switch for a short circuit and for proper wiring.
Check Open Force adjustment (see Set Limit Switches and Force Controls on page 20). Adjust as needed.

Ensure Magnetic Carriage Assembly is engaged to Rail Drive Screw (see Install Magnetic Carriage Assembly
onto Rails on page 10).
Check Force adjustment (see Set Limit Switches and Force Controls on page 20). Adjust as needed.
Check that all sections of Rail Drive Screw are turning when Motor runs. If not:

- Check condition (not cracked, split, or broken) and placement of Coupler. Replace as needed.
- Check condition (not cracked, split, or broken) and placement of Collar and Clip. Replace them

as needed.

Ensure Magnetic Carriage Assembly is in contact with Close Limit Switch.
Check when door is fully closed, that Carriage activates Close Limit Switch. If not,adjust position of Close
Limit Switch (See page 19).

28