7-4. memory channel lockout – Kenwood TS-440S User Manual
Page 20
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

In example 1 we want to scan only Group 2, so we
would press the 2 key. In example 2 we want to scan
Group 1 and Group 2, so we would press the 1 key
and then the
2
key.
Example 1
Example 2
Group 2
Group 1
Group 2
СН20
CH29
OHIO
CHI 9 СИЗО
CH39
1
1 . . . .
. . . J
4.
You can stop scanning, or resume scan using the
same
methods
described
above
for
the
entire
memory scan.
3-7-2. Program scan
Two programmable scan ranges are provided on the
TS-440S transceiver. PG.S-1 (Program Scan range 1)
utilizes memory channels 06 and 07 to specify the up
per and lower scan limits. PG.S-2 (Program Scan range
2) utilizes memory channels 08 and 09 to specify the
upper and lower scan limits.
Note: -----------------------------------------------------------------------------
The TS-440S microprocessor remembers the various
scan parameters that you have specified and will fol
low whatever you have entered the next time you
press the SCAN key.
Example 1: Memory mode
Previously
programmed
memory
scan
data was to scan channels 20-29 and
40-49.
To scan this same range again simply
press the SCAN key.
Example 2: VFO mode
Previously
entered
program
scan
data
was to scan both PG.S1 and PG.S2.
To initiate program scan over these two
ranges again simply press the SCAN key.
The TS-440S will continue to execute scan according
to the above parameters until you manually change the
information. This saves a lot of key strokes if you al
ways scan the same ranges, etc.
To initiate PG.S
1. Press the VFO/M key to select VFO operation.
2. Press and hold the SCAN key.
3.
To initiate PG.S 1 press the
6
key, and then release
both the
6
and the SCAN keys. Scan will begin on
the
frequency
programmed
in
memory
channel
number
6
and proceed in 10 Hz steps to the upper
limit stored in memory channel 7, then return to
channel
6
and begin again.
CH6
14. 010. 00
cw.-----
PG.S-1-------- 1
CH7
14. 100.00
4. To initiate PG.S 2 press the
8
key, and then release
both the
8
and the SCAN key. Scan will proceed
in the limits specified in memory channels
8
and
9, just as for PG.S 1.
I----- PG.S-2--------- 1
CH8
CH9
14.200.00
14.320.00
USB
T
If you want to scan both ranges PG.S 1 and PG.S
2
, press the
6
and then the
8
key while holding the
SCAN key down, and then release the SCAN key.
Scan will proceed thru the limits in memory chan
nels
6
and 7, thru the limits in memory channels
8
and 9, and then return to begin the process again.
3-7-3. Scan speed
Two scan speeds are available with the TS-440S.
To change the speed press the SCAN key after you
have initiated scan. You will be able to toggle between
fast and slow each time you press the key.
Note: ----------------------------------------------------------------------------
The scan step size depends upon the mode that has
been selected for SSB, CW and AFSK the step size is
10 Hz, for FM and AM the step size is 100 Hz.
3-7-4. Memory channel lockout
This transceiver has a memory channel lockout func
tion which allows you to temporarily skip unwanted
memory channels during memory scan.
1
.
2.
3.
Press the VFO/M key to enter the memory mode.
Select the memory channel that you want to skip
using the numeric keypad, the TUNING knob, or the
UP/DOWN microphone or BAND switches.
Press the CLEAR switch.
M CH
(_ -I /
/.
/
~1 c n
I -Uj
4. A decimal point will appear in the M.CH display to
indicate that the channel will be skipped.
C -I.
I
U
/ “ > / _ / /
I I. I I
_ / .
U
CH6
cw
-PG.S-1-
PG.S-2
СН7
T
CH8
-H---
СН9
USB
6
.
To stop scanning press the PTT switch, or the
CLEAR key. Pressing the SCAN key allows scan to
resume from the point you stopped.
To cancel the lockout, select the desired channel
and then press the CLEAR switch. The decimal
point will go out indicating that the channel will
again be scanned.
-
I U
I 1 U I I
c
r #
I I.
I I J.U
18