5. MAINTENANCE AND ADJUSTMENT

5-1. GENERAL INFORMATION

Your transceiver has been factory aligned and tested

to specification before shipment. Under normal circum­

stances the transceiver will operate in accordance with

these

operating

instructions.

All

adjustable

trimmers

and coils in your transceiver were preset at the facto­

ry and should only be readjusted by a qualified techni­
cian with proper test equipment.

Attempting

service

or

alignment

without

factory

authorization can void the transceiver's warranty.

When operated properly, the transceiver can give years

of service without requiring realignment. The informa­

tion in this section gives some general service proce­

dures

which

can

be

accomplished

without

sophisticated test equipment.

5-2. SERVICE

Should it ever become necessary to return the equip­

ment to your dealer or service center for repair, pack

in its original box and packing, and include a full

description of the problems involved. Also include your

telephone

number.

You

need

not

return

accessory

items unless directly related to the service problem.

You may return your radio for service to the Autho­

rized TRIO-KENWOOD Dealer from whom you pur­

chased it. A copy of the service report will be returned

with the unit. Please do not send sub-assemblies or

printed circuit boards. Send the complete unit, in its

original boxes and packing.

Tag all returned items with your name and call for iden­

tification. Please mention the model and serial num­

ber of your radio in any correspondence, whether

phone or written. For future reference, record this in­

formation in the space provided on the back cover of

this manual.

Service note:---------------------------------------------------------------

Dear OM, if you desire to correspond on a technical

or operational problem, please make your note short,
complete, and to the point. And PLEASE make it

readable.

Please list:

Model and serial number.

The question or problem you are having.

Please give sufficient detail to diagnose: other equip­

ment in the station, meter readings and anything you

feel might be useful in attempting diagnosis.

Caution: --------------------------------------------------------------------

Do not pack the equipment in crushed newspapers for

shipment!

Extensive

damage

may

result,

during

shipping.

Notes: -----------------------------------------------------------------------

1.

Record the date of purchase, serial number and

dealer from whom purchased.

2.

For your own information, retain a written record

of any maintenance performed on the unit.

3.

When claiming warranty service, please include a

photocopy of the bill of sale, or other proof of pur­

chase showing the date of sale.

5-3. CLEANING

The knobs, front panel and cabinet of the transceiver

are likely to become soiled after extended use. The

knobs should be removed from the transceiver and

cleaned with a neutral soap and warm water. Use a

neutral soap (not harsh chemicals) and damp cloth to
clean the cabinet and front panel.

5-4. IN CASE OF DIFFICULTY

The problems described in this table are failures caused

in general by improper operation or connection of the

RECEPTION

transceiver,

not

by

defective

components.

Examine

and check according to the following table. If the

problem persists, contact an authorized agent or serv­
ice station.

Symptom

Probable cause

Corrective action

Indicators do not light and no receiver

noise is heard when the POWER

switch is turned on.

1. Bad power cable or connections.

2. Blown power supply fuse.

3. Power supply is OFF.

1. Check cables and connections.

2.

Check for the cause of the blown fuse

and replace the fuse.

Nothing is displayed or wrong digits

are displayed when the POWER

switch is turned on.

The

microprocessor

malfunctions.

This

occurs when the battery is old or the sup­

ply voltage drops extremely on the occa­

sion of consuming large current.

1.

Adjust the supply voltage to nominal

voltage ±10V with use of a boost­

ing transformer.

Use a 12 to 16V battery.

2. Turn the POWER switch on again.

No signal is received even when the

antenna is connected.

1. SQL control fully clockwise.

2.

Microphone PTT switch is in the trans­

mit position, and the TS440S is in the

transmit mode.

3.

SELECTIVITY switch is set to "N" or

"Ml'' and no optional filter is installed.

1.

Turn

the

SQL

control

counter­

clockwise.

2.

Set the PTT switch to the receive

positon.

3.

Ensure the SELECTIVITY switch is set

to either "AUTO", "M2", or "W"

An antenna is connected, but no sig­

nal is received and the S-meter fully

deflects.

RF control is too low, decreasing the high

frequency circuit gain.

Turn the RF gain control fully clockwise.