Crosman CP432C User Manual

Warning, Advertencia

Advertising
background image

3

4

5

2

1

Mounting the Scope
CAUTION: Always ensure your rifle is UNLOADED, UNCOCKED and the safety is applied before fitting the
scope. Practice safe handling procedures at all times.

• The ring mounts included with this scope feature a removable recoil pin sited under-

neath the rear ring. Use supplied hex wrench to adjust the pin and slot it in to the
recess of certain air rifle models to prevent the mount moving rearward under heavy
recoil. Line the recoil pin up with the rear hole on the tube. For rifles that do not
have this recess, simply remove the top half of the ring mount and unscrew the recoil
pin to remove it.

• Remove the ring mount screws (C-F) and lift the scope from the mounts.
• Loosen the mounting screws (A-B) on the base of the mounts.
• Tighten the ring base mounting screws.
• Mount the front base and place the scope on the rail with the ocular lens toward the

rear of the gun.

• Put the rifle to your shoulder in your natural shooting position and adjust the scope’s eye relief until you

achieve a full field of view.

• When you have found the ideal eye relief rotate the scope so the reticle cross hairs are vertical and perpen-

dicular to the rifle.

• Replace the ring mounts and ring mount screws.
• Tighten the screws on the ring to ensure a firm grip on the scope. NOTE: Do not over tighten the screws

as you could cause damage to the scope body.

Variable Power Adjustments (For 3-9x32 Model Only)
To change the magnification, simply rotate the magnification ring to align the desired magnification with the index dot.

CenterPoint Precision Optics
7629 Routes 5 & 20
East Bloomfield, NY 14443
www.centerpointoptics.com
1-866-726-1122

CP432C-515

BUYER AND USER HAVE THE DUTY TO OBEY ALL LAWS ABOUT THE USE AND OWNERSHIP OF THIS
SCOPE.

All CenterPoint scopes are constructed with high quality precision machined parts. The rugged one piece tube
construction works for all terrains and weather. The scope is precision machined to exact tolerances from air-
craft-grade aluminum alloy.

Learning the parts of your scope
Learning the names of the parts of your new scope will help you to understand your owner's manual.

CP432C / CP392

OWNER'S MANUAL

READ ALL INSTRUCTIONS AND WARNINGS IN THIS

MANUAL BEFORE USING THIS SCOPE

Maintenance

• Take care not to drop or knock the scope once it is zeroed.
• Keep the protective lens covers in place when the scope is not being used.
• Store the scope in a cool dry place when not in use.
• Be careful to avoid contact with acid, alkaline or corrosive chemicals.
• Do not attempt to lubricate any part of the scope.
• Do not disassemble the scope. Do not loosen or remove any screws or parts. Any such or similar actions

will void the warranty.

• Wipe the lens with a clean flannel cloth to keep it clean and dry. Do not use finger or finger nail to touch or clean

lenses.

• Use only a clean flannel cloth for cleaning.
• To maintain battery life, in RG models, turn illumination off when not in use.

1. Magnification Ring (For 3-9x32 Model Only)

5. Objective lens

2. Fast Focus Eyepiece

6. Removable Elastic Lens Covers

3. Ocular Lens

7. Windage (horizontal) Adjustment

4. Elevation (vertical) Adjustment

LIMITED LIFETIME WARRANTY ON CENTERPOINT SCOPES

Your CenterPoint scope is warranted to be free of defects in materials and workmanship for the lifetime of
the original owner. This warranty does not cover damages due to fair wear and tear, failure to provide rou-
tine maintenance, and does not include batteries or accessories. This warranty lasts as long as the origi-
nal purchaser owns the product, and is not transferable. In the event of a defect under this warranty, we
will, at our option, repair or replace the product provided our inspection indicates that an original defect
exists. CenterPoint reserves the right to replace any product which is no longer available with a product of com-
parable value and function. If CenterPoint determines the repair is not covered under the warranty guidelines,
there could be a charge to you for the repair. This is a limited warranty and does not cover damages caused by mis-
use, improper handling or installation or maintenance provided by someone other than a CenterPoint
Authorized Service Station.

This limited warranty does not include consequential damages, incidental damages, or incidental expenses,
including damage to property or any other expense. CenterPoint disclaims any implied warranties. Some states
do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on implied
warranties so the above limitations or exclusions may not apply to you. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state and country to country.

WARRANTY CLAIMS/ REPAIR SERVICE
If your scope needs repair, call CenterPoint Customer Service at 1-800-726-1122 or visit our web site at
www.centerpointoptics.com DO NOT ATTEMPT TO DISASSEMBLE IT! Any disassembly or modification not
performed by an Authorized Service Station will void the warranty.

USA Customers: Please contact CenterPoint before shipping your product. Include with product your name, address,
description of problem, phone number and copies of sales receipt and warranty. A check or money order in the
amount of $10.00 to cover the cost of postage and handling is also required. Package and return to CenterPoint,
Crosman Corporation, 7629 Rts. 5 & 20, E. Bloomfield, NY 14443. CenterPoint will not assume any responsibility for
any loss or damage incurred in shipping.

Canadian Customers: Contact Crosman Parts and Service at (705) 749-0206 before shipping your product. Follow
packaging and shipping procedures above and send to Crosman Parts & Service Depot, 611 Neal Drive, Peterborough,
Ontario K9J 6X7 Canada. Shipping and handling costs may apply.

Other International Customers: Please return product to your nearest distributor. If you do not know your
distributor, please call 585-657-6161 and ask for our International Department for assistance. Shipping
and handling costs may apply.

Direct viewing of the sun can cause permanent eye damage. Do not
attempt to view the sun through this riflescope or any other optical

instrument.

WARNING:

Model

CP432C

CP392

Magnification

4x

3x-9x

Objective Diameter (mm)

32

32

Exit Pupil (mm)

6

10.0 - 3.5

Eye Relief (inches)

3.5

3.3

Field of View (@ 100yds)

28’

39.0’ - 13.0’

Tube Diameter (inches)

1

1

Length (inches)

7.8

12.5

Weight (ounces)

10.4

16.6

W/E Adjust Click Value

1/4 MOA

1/4 MOA

Parallax Setting (yds)

35

35

Specifications

Always follow all rules of firearm and gun safety.

WARNING:

7

Range Estimating
Range estimating requires common knowledge/experience about your target's actual width or height. Use the the
Mil Dot instruction card in the scope box for the specific formula for your scope model.

C/D

E/F

B

A

Zeroing the Scope
The purpose of zeroing the scope is to ensure that the scope is aligned with the impact point of the pellet
or bullet from the rifle. Before zeroing the scope, read the following adjustment knob instructions carefully.

• Place a target 100 yards away.
• Ideally use a steadying device such as a bipod or shooting stand, set the scope at the high-

est magnification, aim at the center of the target and fire a test shot, if safe to do so.

• If the impact point of the pellet or bullet is exactly in the center of the target then the scope is

zeroed. If it is not, you will need to adjust the reticle using the elevation and/or windage
adjusters.

• Remove the caps from the windage and elevation dials
• Vertical Adjustment (Elevation) - Use your fingers to turn the adjusting knob as

required. One click in either direction equals approximately 1/4 inch at 100 yards.

• Horizontal Adjustment (Windage) - Use your fingers to rotate the adjusting knob as

required. One click in either direction equals approximately 1/4 inch at 100 yards.

• Having adjusted the windage and elevation as required, fire, if safe to do so, another test shot. Keep

adjusting and test firing until the test shot impacts on the center of the target when the reticle is on
the center of the target. This is vital for accurate shooting.

• Once the scope is zeroed, be sure to put the windage and elevation caps back on.

Note: Each click of adjustment moves the impact point by the amount shown in the table below.

@ 50yds

@ 100yds

@ 200yds

@ 300yds

1/8”

1/4”

1/2”

3/4”

6

3

4

5

2

1

Montaje de la mira telescópica
PRECAUCIÓN: Antes de instalar la mira telescópica, asegúrese siempre de que el rifle
esté DESCARGADO Y DESAMARTILLADO y que el seguro esté aplicado. Practique pro-
cedimientos de manipulación seguros en todo momento.

• Las monturas de anillo incluidas con esta mira telescópica tienen un perno de retro-

ceso removible situado debajo del anillo posterior. Use la llave allen incluida para
ajustar el perno y colocarlo dentro del hueco de algunos modelos de rifle para evitar
que la montura se mueva hacia atrás cuando hay un fuerte retroceso. Alinee el tornil-
lo de fijación con el orificio posterior del tubo. En el caso de los rifles que no tienen
este hueco, sólo debe quitar la mitad superior de la montura de anillo y destornillar el
perno de retroceso para quitarlo.

• Quite los tornillos de la montura de anillo (C-F) y levante la mira telescópica de las monturas.
• Afloje los tornillos de montaje (A-B) en la base de las monturas.
• Apriete los tornillos de montaje de la base del anillo.
• Monte la base delantera y coloque la mira telescópica en el riel con el lente ocular hacia la parte posterior del arma.
• Colóquese el rifle en el hombro en su posición natural de disparo y ajuste la distancia del ojo hasta que consi-

ga una vista de todo el campo.

• Cuando haya encontrado la distancia del ojo ideal, gire la mira telescópica de modo que las marcas en cruz de la

retícula estén verticales y perpendiculares al rifle.

• Vuelva a colocar las monturas de anillo y los tornillos de las monturas de anillo.
• Apriete los tornillos del anillo para asegurar un agarre firme de la mira telescópica. NOTA: No apriete los tornil-

los en exceso ya que podría ocasionarle daños al cuerpo de la mira telescópica.

Ajustes de potencia variable(sólo en modelos 3-9x32)
Para cambiar el aumento, simplemente gire el anillo de aumento para alinear el aumento deseado con el punto de índice.

Modelo CP432C / CP392

MANUAL DEL PROPIETARIO

LEA TODAS LAS INSTRUCCIONES Y ADVERTENCIAS DE ESTE

MANUAL ANTES DE USAR LA MIRA

1. Anillo de aumento

(sólo en modelos 3-9x32)

5. Lente del objetivo

2. Ocular de enfoque rápido

6. Tapas de los lentes removibles con bisagra

3. Lente ocular

7. Ajuste de compensación de viento (horizontal)

4. Ajuste de elevación (vertical)

7

EL COMPRADOR Y EL USUARIO TIENEN EL DEBER DE OBEDECER TODAS LAS LEYES RELATIVAS AL
USO Y PROPIEDAD DE ESTA MIRA TELESCÓPICA.

Todas las miras telescópicas CenterPoint están construidas con piezas mecanizadas de precisión de alta calidad.
La resistente construcción de tubo de una pieza funciona para todos los terrenos y climas. La mira telescópica está
mecanizada con precisión a tolerancias exactas a partir de aleación de aluminio de grado de aeronave

.

Aprendiendo las partes de su mira telescópica
Aprendiéndose los nombres de las partes de su nueva mira telescópica le ayudará a entender su manual del propietario.

La visión directa del sol puede ocasionar daños permanentes al
ojo. No intente ver el sol a través de esta mira telescópica del rifle

ni de ningún otro instrumento óptico.

Advertencia:

Siempre siga todas las reglas de seguridad para armas de fuego.

Advertencia:

6

Cálculo de alcance
El cálculo de alcance requiere un conocimiento común o experiencia acerca de la altura o anchura reales de su
blanco. Use la tarjeta de instrucciones de Mil Dot de la caja de la mira telescópica para conocer la fórmula específi-
ca de su modelo de mira telescópica.

Ajuste en cero de la mira telescópica
El objetivo del ajuste en cero de la mira telescópica es asegurarse de que la mira telescópica esté alineada con el
punto de impacto del diábolo o la bala procedentes del rifle. Antes de ajustar la mira telescópica en cero, lea cuida-
dosamente las siguientes instrucciones para el ajuste de la perilla.

• Coloque un blanco a 100 yardas (91.4 m).
• Idealmente, use un dispositivo de estabilización como un bípode o pie de tiro, coloque la

mira telescópica en el máximo aumento, apunte al centro del blanco y dispare un tiro de
prueba si es seguro hacerlo.

• Si el punto de impacto del diábolo o de la bala está exactamente en el centro del

blanco, entonces la mira telescópica está ajustada en cero. Si no lo está, deberá
ajustar la retícula usando los ajustadores de elevación o compensación de viento.

• Retire las tapas de los selectores de compensación de viento y elevación.
• Ajuste vertical (elevación) - Gire con los dedos la perilla de ajuste según sea necesario. Un

clic en cualquier dirección es igual aproximadamente a 1/4 de pulgada a 100 yardas (0.63
cm a 91.4 metros).

• Ajuste horizontal (compensación de viento) - Gire con los dedos la perilla de ajuste según sea necesario. Un

clic en cualquier dirección es igual aproximadamente a 1/4 de pulgada a 100 yardas (0.63 cm a 91.4 metros).

• Habiendo ajustado la compensación de viento y la elevación según sea necesario, dispare, si es seguro, otro

tiro de prueba. Siga ajustando y haciendo disparos de prueba hasta que el tiro de prueba impacte el centro
del blanco cuando la retícula está en el centro del blanco.. Esto es esencial para disparar con precisión.

• Una vez que la mira telescópica esté ajustada en cero, cuide de volver a poner las tapas de compensación de

viento y elevación.

Nota: Cada clic de ajuste mueve el punto de impacto por la cantidad mostrada en la tabla que aparece abajo.

C/D

B

A

Mantenimiento

• Cuide de no dejar caer ni golpear la mira telescópica una vez que la haya ajustado en cero.
• Conserve en su sitio las tapas protectoras de los lentes cuando no esté usando la mira telescópica.
• Guarde la mira telescópica en un lugar fresco y seco cuando no la utilice.
• Cuide de evitar el contacto con sustancias químicas ácidas, alcalinas o corrosivas.
• No intente lubricar ninguna parte de la mira telescópica.
• No desarme la mira telescópica. No afloje ni quite ningún tornillo o pieza. Cualquier acción así o similar anu-

lará la garantía.

• Limpie la lente con un paño de franela limpio para mantenerla limpia y seca. No use el dedo o la uña para

tocar o limpiar las lentes.

• Use sólo un paño de franela para la limpieza..

@ 50yds

@ 100yds

@ 200yds

@ 300yds

1/8”

1/4”

1/2”

3/4”

Advertising
This manual is related to the following products: