4.4. Weighing Modules for the Operation of Standard Load Cells
The weighing system controller can accommodate up to two weighing modules. Depending on the application –
legal for trade scale or industrial application – it can be selected among various weighing modules.
Weighing module type
LDU 68.1
LDU 69.1
LDU 78.1
LDU 68.2
Accuracy class
Not approved
Certificate no.
DK0199-R76-
10.04 Rev.1
DK0199-R76-
11.08 Rev. 1
DK0199-R76-
10.08 Rev. 1
Intervals "n" acc. Kompmodeng:
n
ind
10.000
10.000
10.000
Internal resolution
± 130 000
> ± 1 000 000
± 260 000
± 130 000
Approved single range scale
yes
yes
yes*
no
Approved multi range scale
no
yes
yes*
no
Approved multi interval scale
no
yes
yes*
no
Load cell excitation
U
EXC
5 V DC
5 V AC
5 V DC
5 V DC
Minimum input voltage
U
MIN
0 V
0 V
0 V
0 V
Approved min. input per vsi
∆
U
min
1.0
µ
V
0.1
µ
V
0.3
µ
V
Input sensitivity
0.05
µ
V/d
0.02
µ
V/d
0.05
µ
V/d
0.1
µ
V/d
Min. load cell impedance
R
Lmin
87.5
Ω
87
Ω
87.5
Ω
87.5
Ω
Max. load cell impedance
R
Lmax
1150
Ω
1200
Ω
1150
Ω
1150
Ω
Min. operation temperature
T
min
-15 °C
-15 °C
-15 °C
-15 °C
Max. operation temperature
T
max
+55 °C
+55 °C
+55°C
+55 °C
Fractional error limit
P
ind
0.5
0.5
0.5
Load cell connection
4-/6- wire technique
4/6
4/6
4/6
4/6
Factory sensor addresse (RS485-ID)
1 (2)
3 (4)
5 (6)
7 (8)
Tab. 4.3: Technical characteristics of weighing modules
Hint: If two weighing modules of the same type are used, then the sensor address of the second module is
increased by one (see RS485-ID in parentheses).
4.5. Weighing Module Upgrade
You can upgrade the weighing system controller with a second weighing module. Auch eine Umrüstung der
Wägemodule ist möglich.
ATTENTION: LEGAL FOR TRADE APPLICATIONS
If any of the relevant weighing components will be changed, the operating license als legal for trade scale
expires. Please read chapter 9 to this.
IMPORTANT:
For all service operations use an appropriate protection against electrostatic
discharge. Follow the safety instructions within the operation manual of your
instrument.
Step 1:
Shut down your operating system. Disconnect the weighing terminal from the power
source. Open the enclosure of the weighing terminal.
Step 2:
Remove the interlock of the PCI plug-in card. Afterwards you can take out the
weighing system controller.
Step 3:
(only for retrofit)
Remove the wire strap from the weighing module to replace and remove the two M3
x 6 mm cross slot screws. Pull out the weighing module.
Step 4:
Insert the new weighing module into the corresponding socket. Secure the weighing
module by fastening the supplied M3 x 6mm cross slot screws.